Metrologic Instruments TECH 10, 1070 manual Installation of the Stand

Page 9

INSTALLATION OF THE STAND

With the Metrologic stand (Part #45-45479), the scanner can be positioned in a vertical orientation. To use this stand, four 6-32 x ½" machine screws and two #10 panhead wood screws will need to be purchased. The maximum distance the screws should go into the scanner is ½ inch.

1.Lay the scanner face down on a clean cloth to prevent any scratches from occurring on the output window. Position the scanner so the red and green LEDs are pointed toward you.

2.Lay the stand on top of the scanner with the angled bracket pointing up and toward you.

3.Align the four clearance holes to the four holes in the scanner’s case. Fasten the stand to the scanner by inserting the four 6-32 x ½" screws into the four holes in the scanner’s case.

4.Drill two holes into the work surface that correspond with the holes in the 254 mm x 95 mm (10" x 3.75") base of the stand.

5.Use the two #10 panhead wood screws to attach the stand and scanner to the work surface.

(Refer to Figure 1)

Figure 2

5

Image 9
Contents November Page North America LocationsTable of Contents Introduction Scanner and AccessoriesScanner Connections to the Host Configuration of the Scanner to the Host System Parts of the Scanner Installation of the Stand Page Labels Scanning bar codesMaintenance Appendix a SpecificationsMechanical ElectricalEnvironmental OperationalPin Assignments for the Mil spec Connector Appendix BPIN Function Limited Warranty Appendix CUSA Corporate Headquarters Germany Remarque Appendix DAtención AchtungAppendix D European Standard Funkstöreigenschaften nach EN WarnungStandard Europeo Attenzione Patents Appendix EIndex RMA