Metrologic Instruments SP5600 manual Installation

Page 13

Installation

3.Follow steps a, b, or c

a.For the RS232 cable plug the 9 pin serial connector into a serial port on the host device. Plug the opposite end into the communication port of the cradle.

b.For the USB cable plug the USB end of the cable into an appropriate communication port on the host device and the opposite end of the cable into the communication port of the cradle*.

c.For the WiFi connection to communicate with the host device the settings on OptimusR and the host device must be configured correctly.

4.Power up the Optimus and select the Utilities option.

5.This will open additional menu options. Select the Transfer Files option.

6.Select Get Program on the next menu. The unit is now ready to download an application program.

7.Place unit in cradle and download the appropriate application program.

8.Once the Optimus has received the application program the unit is ready for scanning and collecting data.

Note: There are OptimusR models available that do not include the cradle. Models that do not include a cradle as an accessory can have the power supply and the communication cable connected directly to the unit.

*A software driver is required for proper installation. The driver is included with the installation CD provided with each Optimus. In addition the driver can be downloaded from http://www.metrologic.com.

11

Image 13
Contents SP5600 OptimusR User’s Guide Page Page Table of Contents Page Introduction Scanner and AccessoriesProduct Overview Description General Features and CharacteristicsCradle Features Multifunctional Keypad Alphanumeric Arrow ESC Scan Enter Functionfn PowerLCD Screen Lithium-Ion BatteryGetting Started InstallationBasic Operation Communication and Data Collection SetupInstallation Data Upload System Menu Information Settings Tests Memory Power Load Program MenuSystem Menu Options InformationLCD & LED Initialize Size Info802.11b Menu Wlan SettingNetwork Set SecurityRun Program Utilities ApplicationProgramming the terminal Programming the communication cradleSymptom TroubleshootingSingle-Line SpecificationsEMC Corporate Headquarters Contact Information and Office LocationsUnited Kingdom Safety Notices