Metrologic Instruments MS770 manual Back Plate Installation

Page 7

Back Plate Installation

 

With the Metrologic back plate

 

(Part #45473), position the scanner

 

in one of two directions. The two

 

orientation choices are vertical or

 

horizontal. (Refer to Figure 4). To

 

use this stand, use the four 6-32 x ½

 

inch machine screws and four wood

 

screws to attach the unit to the back

 

plate and work surface. The maxi-

 

mum distance the screws should go

Figure 4

into the scanner is a ½ inch.

 

1.Drill four holes into the work surface that correspond with the holes indicated by an XY in Figure 5.

2.To fasten the scanner to the back plate:

!For a horizontal mount, align the four holes on the back of the scanner with the four clearance holes located on the back plate marked with an X in Figure 5.

!For a vertical mount, align the four holes on the back of the scanner with the four clearance holes located on the back plate marked with a Y in Figure 5.

3.Fasten the scanner to the back plate by inserting the four 6-32 x ½ inch screws into the four holes in the scanner’s case. Fasten the scanner and back plate to the work surface.

Figure 5

5

Image 7
Contents Metrologic INSTRUMENTS, INC Installation and User’s GuideTable of Contents Unpacking List IntroductionScanner Installation Configuration to the Host System Stand Installation Back Plate Installation Code has been decoded Parts of the ScannerSteady Green Visual IndicatorsNi la diode rouge, ni la diode verte nest allumée Signaux optiquesWeder rote noch grüne Leuchtdiodenanzeige Optische AnzeigenNé il diodo luminoso rosso né quello verde sono accesi Segnali otticiLabels Depth of Scan Field for the MS770 Scanner Depth of Scan Field for the MS775 Scanner Applications and Protocols MaintenanceAppendix a SpecificationsOperational Pin Assignments Appendix BVersion 15 Pin Assignments for Light Pen Emulation Appendix C Warranty and DisclaimerDisclaimer Remarque Appendix DAnmerkung Patents Appendix EAsic IndexMecca