C H A P T E R 2
Hardware Modifications
Power Requirements
Power drawn for the 200 MB hard disk must be less than or equal to values shown in Table
Table
|
|
| Current (amps) |
|
| Power (watts) |
Mode | Mean | Maximum | Mean | Maximum | ||
Startup (1) | Not | 1.30 | Not | 6.50 | ||
| applicable | applicable | ||||
Random | 0.50 |
| 0.60 | 2.50 |
| 3.00 |
operation (2) |
|
|
|
|
|
|
Idle | 0.30 |
| 0.38 | 1.50 |
| 1.90 |
Standby | 0.20 |
| 0.25 | 1.00 |
| 1.25 |
NOTE | 1 | Startup values are peak values during response time of Power On to |
Power Ready. | ||
NOTE | 2 | Random operation values are RMS values with a 40 percent random seek, |
40 percent write/read (1write in 10 reads) and 20 percent idle mode.
14 | 200 MB Hard Disk Drive |