Siemens SANTIS-ab user manual Configuration Example

Page 24

Configuration Example 2:

A fax machine gr.3 is connected to the a/b1-interface. Thus the MSN and HLC are to be set:

MSN = 456, HLC = fax gr.2/3 for a/b1.

1. Hook off and wait for dial tone, then dial

2. ∗∗ → the dial tone is switched off

111 456 # → 1st MSN for a/b1

3.When the permanent tone is switched on proceed to 4 and dial

4.221 2 # → HLC for a/b1

5.When the permanent tone is switched on, hook on.

24

Image 24
Contents SANTIS-ab Siemens Contents Safety Instructions Operating Modes NT+2abPairgain Installation Page Configuration Page Page Page Table of Configuration Commands Parameter-ResetRestrictions for NT+2ab/CA restr. and Pairgain Multiple Subscriber Number MSN Hot Line Emergency Mode Priority Switch RestrictionsType of Terminal Selection HLC HLCClear Back Time Delay Switch PABX-Switch Metering Pulse Switch Call Waiting Tone Switch ∗∗ 390 100 # Metering CalculationCalling Line Identification Restriction Clir Switch 210 1 # Configuration Example Remarks Troubleshooting Pin Allocations of the Sockets USER11.DOC