Note:
1.
2.
3.
Warning:
-When the copper port is set to AUTO and is connected to a device that is forced to 100Mbps FDX, an unknown state may result.
-Please ensure that all network nodes that this device connects to are set to the same mode at each end of the link.
e.g., Both ends are set to
9. Cable Distances and Limitations
-TP Cable Limitations: Cat 5 up to 100m
-Fibre Cable Limitations:
SC/ST Converter Models
Multi Mode Half Duplex | 412m |
Multi Mode Full Duplex | 2Km |
Single Mode Half Duplex | 412m |
Single Mode Half Duplex | 5/20/40/60/80/100Km |
10.Technical Specifications
Standards: | IEEE 802.3u |
| IEEE 802.3af Power Over Ethernet |
UTP Cable: | Cat. 5 cable up to 100m |
Fibre Cable: | 50/125, 62.5/125 or 100/140 µm multi mode |
| 8.3/125, 8.7/125, 9/125 or 10/125 µm single mode |
Power Feeding | Via TP Pins 1, 2, 3 and 6 |
Support: |
|
LED Indicators: | Power, POE, TP LNK/ACT, 100, FX LNK/ACT, |
| FDX/COL, 4W, 7W, 15.4W |
Data Transfer Rate: | 100Mbbps – 148,800pps |
| 10Mbps – 14,880pps |
Flow Control: | IEEE 802.3x compliant for Full Duplex |
| Backpressure flow control for Half Duplex |
Power Requirements: | AC 100 ~ 240V 50 ~ 60Hz |
Power Consumption: | 24W |
Ambient Temperature: | 0º to 50º C |
Humidity: | 5% to 90% |
Dimensions: | 40(H) x 158(W) x 133(D) mm |
Complies with