Altinex manual Installing Your PNP400

Page 14

DESIGNER SOLUTIONS

INSTALLING YOUR PNP400

6

Step 1. Refer to the ALTINEX website, www.altinex.com, to download the latest templates and instructions for tabletop cutting requirements and installation.

In order to do this, locate the PNP400 on the website and go to its detail page. The links to the templates, user’s guide, and more are on the left-hand side of the screen.

NOTE: The table can be 0.25-4.0 in (6-102 mm) thick.

Step 2. Print all information applicable to the installation of the PNP400, including the templates and any detailed installation instructions.

Step 3. Mark the table’s surface to indicate the correct positioning of the unit. The face of the unit is typically parallel to the longest sides of the tables.

Step 4. Cut an opening into the table’s surface. This operation should be performed by experienced professionals in order to insure accuracy and to be aesthetically pleasing.

NOTE: Always confirm dimensions before cutting to insure that specifications have not changed.

Step 5. Lower the PNP400 into the opening in the table and make sure the bezel of the unit sits evenly in the table.

Step 6. From under the table, insert the mounting brackets into the slots on the side of the unit. See DIAGRAM 6 on page 10 for details. Place the brackets at the desired height for the table thickness and secure them to the bottom of the table using the thumb screws provided. There are two support brackets, one for each side of the unit.

Step 7. Secure the power cord using the cable clamp provided. Pass the power cord (if any) from the bottom of the housing and attach it to the table leaving a service loop beneath the unit. Before tightening the clamp, open and close the unit from the top several times. Set the service loop for smooth operation only. Do NOT leave excessive cable hanging below the table.

Step 8. Secure other cables from the PNP400 to the table separate from the power cord. All cables should be secured using a service loop to allow the unit to open and close easily.

Step 9. Once you have connected power and the proper cables to the unit, you may raise the unit. To raise the PNP400 into position, press the top of the unit.

Step 10. To lower the PNP400, push on the top of the unit until it locks into place. Do NOT use excessive force to press down on the pop-up.

400-0109-006

13

Image 14
Contents PNP400 Table of Contents General Precautions / Safety WarningsCleaning HandlingTechnical Specifications About Your PNP400Product Description Application Diagrams Diagram 1 Typical SetupDiagram 2 Cutout Diagram 3 TOP View Diagram 4 Front View Diagram 5 Side View Diagram 6 Mounting TabletopDiagram 7 Accessory Installation Cutout Covers Diagram 8 CABLES/ACCESSORIESReplacement Parts Sectional PlatesInstalling Your PNP400 Limited WARRANTY/RETURN Policies Troubleshooting GuideInstall Sectional Plates Operation