Motorola XPR 8300 Electrical Connections, Power Supply Connections, AC Input Power Connection

Page 27

Chapter 4 Electrical Connections

After the MOTOTRBO Repeater has been mechanically installed, electrical connections must be made. This involves making the following connections:

AC power cord, and

antenna coaxial cables

Figure 4-1shows the position of the various connectors and connections on the rear panel of the repeater.

TX CONNECTOR

RX CONNECTOR

POWER SUPPLY ON/OFF SWITCH

REAR

ACCESSORYMAIN FAN

CONNECTOR

Rx

Tx

GND

GROUND SCREW

POWER

BATTERY SUPPLY FANETHERNET CONNECTOR

BACKUP

CONNECTOR

AC LINE CORD CONNECTOR

Figure 4-1Locations of Connectors on the Rear Panel of the Repeater

4.1Power Supply Connections

4.1.1AC Input Power Connection

!Do NOT apply AC power to the repeater at this time. Make sure that the circuit breaker associated with the AC outlet is turned to OFF.

C a u t i o n

NOTE: The AC source must be installed near the equipment and must be easily accessible.

Each repeater ships with a 2.438 m (8 feet) 3-conductor line cord that connects the repeater to a 110/120/220/240 VAC source. Figure 4-1shows the location where the AC line cord connects to the repeater. Insert the 3-prong plug into a 110/120/220/240 VAC grounded outlet.

If an alternate line cord is required, obtain a suitable line cord, with fittings approved by the safety testing agency in the end-use country, from a certified electrical parts supplier.

Image 27
Contents 6816814H01 Page Foreword Product Safety and RF Exposure CompliancePage Declaration of Conformity Declaration of ConformityPage Table of Contents Chapter Accessories Chapter Mechanical InstallationChapter Indicators and Connectors Chapter Post-Installation ChecklistRelated Publications List of FiguresList of Figures AA M Repeater Model Numbering SchemeRepeater Model Numbering Scheme Limited Warranty Commercial WarrantyIII. State Law Rights VI. Patent and Software Provisions Xiv Operating Temperature Range Pre-Installation ConsiderationsInstallation Overview Environmental Conditions at Intended Installation SiteAir Quality AC Input Power RequirementsEquipment Ventilation Equipment Mounting MethodsLightning Ground Site Grounding and Lightning ProtectionElectrical Ground RF GroundPre-Installation Considerations Unpacking Equipment Mechanical InstallationMechanical Installation Indicators and Connectors LED Indicator DescriptionsFront Panel Rear Panel Part Rear PanelRear Accessory Connector Pin Power Supply Connections AC Input Power ConnectionElectrical Connections Ground Connection Battery Backup ConnectionRF Antenna Connections Duplexer SelectionAntenna Selection Electrical Connections Archiving Post-Installation ChecklistApplying Power Verifying Proper OperationPost-Installation Checklist Cables AccessoriesMiscellaneous Accessories AntennasAccessories Fax Orders Appendix a Replacement Parts OrderingBasic Ordering Information Motorola Online Mail Orders Telephone OrdersParts Identification Product Customer ServiceMotorola Federal Technical Center Appendix B Motorola Service CentersMotorola Service Center Servicing InformationMotorola Service Centers Page 6816814H01