Chapter 4 Electrical Connections
After the MOTOTRBO Repeater has been mechanically installed, electrical connections must be made. This involves making the following connections:
•AC power cord, and
•antenna coaxial cables
Figure 4-1 shows the position of the various connectors and connections on the rear panel of the repeater.
TX CONNECTOR
RX CONNECTOR
POWER SUPPLY ON/OFF SWITCH
REAR
ACCESSORYMAIN FAN
CONNECTOR
Rx | Tx |
GND
GROUND SCREW
POWER
BATTERY SUPPLY FANETHERNET CONNECTOR
BACKUP
CONNECTOR
AC LINE CORD CONNECTOR
Figure 4-1 Locations of Connectors on the Rear Panel of the Repeater
4.1Power Supply Connections
4.1.1AC Input Power Connection
!Do NOT apply AC power to the repeater at this time. Make sure that the circuit breaker associated with the AC outlet is turned to OFF.
C a u t i o n
NOTE: The AC source must be installed near the equipment and must be easily accessible.
Each repeater ships with a 2.438 m (8 feet)
If an alternate line cord is required, obtain a suitable line cord, with fittings approved by the safety testing agency in the