Motorola SG 2000 operation manual Forward Path RF Configuration, Single Receiver Mode

Page 65

Section 5

Operation

This section provides information concerning the use of various options and applications required by your system. It may be helpful to refer to Figures 3-1 and 3-2 that illustrate the major components in the SG 2000 lid and RF chassis.

Forward Path RF Configuration

You can configure the SG2-lid motherboard (LIDB) using three different forward path RF options.

Single Receiver Mode

If you are using a single optical receiver module (SG2-LR) it must be installed in position C. An SG2-FJB/P jumper board must also be plugged into the LIDB. Figure 3-1 illustrates the location of this jumper board.

The SG2-LIDB distributes an RF signal from the primary receiver (C) to the RF chassis as illustrated in Figure 5-1:

Figure 5-1 Single receiver

Optical

receiver C

Optical

receiver B

Optical

receiver A

 

SG2-FJB/P

 

 

JXP

JXP

A

RF chassis

JXP

Relay

JXP

SG 2000 Installation and O peration Manual

Image 65
Contents A R L I N E Special Symbols that Might Appear on the Equipment Contents E r a t i o n InstallationTorque Specifications Abbreviations and Acronyms Specification sSG2-LR Tables N t e n t s SG 2000 closed SectionSG 2000 open Features includeRelated Documentation Using this ManualBold type Document ConventionsIf You Need Help Calling for Repairs Mounting Holes HousingSG 2000 housing dimensions front and side view Port locations Port LocationsGaskets Housing gasketsSG2-PS2 power supply Power SupplyNetwork Monitoring ConfigurationTo suit system requirements the RF chassis cover. notation Forward Path Signal flow diagramE r v i e w SG2-LR Receiver SG2-LR receiver functional diagramAnalog Return Transmitters Analog Return PathModel Description Analog return transmittersJXP SG2 transmitter block diagramDigital return transmitters Digital Return PathDS-SG2-DRT-2X/A Options and accessories Options and AccessoriesLevel Control Model Description FunctionSG2-PS2 SG2-SBSG2 SG2-FEOptical input versus 750 MHz gain Gain SelectionOptical input versus 870 MHz gain 10 illustrates the gain option selection chart for 870 MHzRelative level dB versus 750 MHz slope 77 channels Tilt SelectionRelative level dB versus 870 MHz slope 94 channels SG2 870 MHz Slope Chart Analog Channels, 220 MHz DigitalRelative level dB versus 870 MHz slope 110 channels SG2 870 MHz Slope Chart Analog Channels, 120 MHz DigitalN c h S e t u p G u r e 3 2 0 0 0 R F c h a s s i s W e r i n g t h e N o d e Fuse Functi o n Rati ng Ype W e r S u p p l y S e t t i n g s Illustrates the location of the LO-HIjumper Single Power Supply or Commonly Po wered Redundant Supplies I c k C h e c k s F u n c t i o n a l T e s t i n g N u a l G a i n C o n t r o l Analog Retu rn Path R w a r d P a t h P a d d i n g B l e 3 2 0 0 0 p a d c h a r t s t a n d a r d g a i n B l e 3 2 0 0 0 p a d c h a r t h i g h g a i n G u r e 3 N k P e r f o r m a n c e G u r e 3 1 N c h S e t u p Install i n g t h e D S S G 2 D R R B B o a r d O p t i o n G u r e 3 1 S G 2 D R R B b o a r d Install e d G u r e 3 1 C a t i o n o f J X P s o n E p a c k Digital Transmitter Install i n g t h e S t a t u s M o n i t o r O p t i o n 2 0 0 0 a c t i v a t i o n W o r k s h e e t DC powering Splicing Fiber Service cable connection and compression fittingInstallation Mounting bracket-front view Strand Wire MountingMounting bracket-rear and side views Center conductor length Coaxial CablesFiber Cables Housing lid and fiber spool tray Fiber spool tray Installation Single Receiver Mode Forward Path RF ConfigurationBroadband/Narrowcast Mode Redundant Receiver ModeRedundant receiver Broadband/narrowcastOverride AB Override FunctionalityStatus monitor/MCB operation Status Monitor/Manual Control OperationSplit return Analog Return Path RF ConfigurationRedundant return RF chassis and location of the SG2-RPM/C or SG2-RPM/S board DS-SG2-DRT/A redundant return Digital Return Path RF ConfigurationDS-SG2-DRT-2X/A redundant return DS-SG2-DRT-2X/A split returnRemoving SG 2000 Optical Modules Installing SG 2000 Optical ModulesSG 2000 Optical Modules SG2 LR Optical Receiver Cleaning the Optical ConnectorFeature Description 0.3 Test-point voltage versus optical powerWavelength selection jumper Wavelength Selection JumperSG2 Ifpt Optical Transmitter FeatureDescriptionSG2-IFPT features SG2 FPT Optical Transmitter Transmitter enableSG2-FPT features SG2 Dfbt Optical Transmitter SG2-DFBT featuresSingle red LED that lights if the hybrid current is outside SG2 DFBT/3 Optical Transmitter SG2-DFBT/3 featuresSG2 Eifpt Optical Transmitter SG2-EIFPT featuresDS-SG2-DRT/A DS SG2 DRT/A Digital Return TransmitterDS-SG2-DRT/A features FeatureDS-SG2-DRT-2X/A DS SG2 DRT 2X/A Digital Return TransmitterDS-SG2-DRT-2X/A features DS-SG2-DRT-2X/A installed in SG DS-SG2-DRT-2X/A cable connectorDS-SG2-DRT-2X/A second RF input cable connection SG2-PS Power SupplySG2-PS power supply Parameter Description Status MonitoringDescription Function Manual Control BoardDB test point Alarm test pointPotentiometers ICS1 Through ICS4Off Ingress ControlState Description Table A-1 SG 2000 optical characteristics Parameter SpecificationTable A-2 Station RF characteristics Appendix aParameterSpeci fic ation Parameter Table A-5 SG2-IFPT RF specificationsTable A-6 SG2-FPT RF specifications Table A-8 SG2-DFBT/3 RF specifications Table A-7 SG2-DFBT RF specificationsTable A-10 SG2-DRT/A RF specifications Table A-9 SG2-EIFPT RF specificationsTable A-11 SG2-DRT-2X/A RF specifications Minimum Optical Model Output Power DBmOption Watts ac Amps Power @90V @60V @52V @44V Table A-14 SG2-75 performance, with 77 channels Channels Link Launch SystemTable A-15 SG2-87 performance, with 94 channels Table A-16 SG2-87 performance, with 110 channelsTorque Fastener Screw Size Wrench Size In-lbs Ft-lbs DBm DBcDBmV MHzSnap connector Return for service authorizationNational Television Standards Committee Optical modulation indexMgbi