ADTRAN FT1 specifications General, L1-5, Issue 1, December, Clei Code # T1R6GMJDAA

Page 1

C A U T I O N !

Section 61245211L1-5

Issue 1, December 1998

SUBJECT TO ELECTROSTATIC DAMAGE

OR DECREASE IN RELIABILITY.

CLEI Code # T1R6GMJDAA

HANDLING PRECAUTIONS REQUIRED.

 

PRACTICES

SINGLE-WIDE FT1 REPEATER

INSTALLATION/MAINTENANCE

 

 

Contents

 

1.

General

................................................................................

1

2.

Installation

3

3.

Installation of FT1 Repeaters in ADTRAN

 

 

Apparatus Cases

3

4.

Maintenance

4

5.

CSA Deployment Guidelines

5

6.

Specifications

6

7.

Warranty and Customer Service

6

Appendix A. FT1 Loopbacks

A-1

 

 

Figures

 

Figure 1. ADTRAN Single-Wide FT1 Repeater

1

Figure 2.

ADTRAN Single-Wide FT1 Repeater

 

 

 

Connector Pinout

3

Figure 3. FT1 Repeater Network Loopback

4

Figure 4.

CSA Deployment Guidelines

5

Figure A-1. FT1 Loopbacks

A-1

Figure A-2. FT1 DP Network Loopback

A-1

Figure A-3. FT1 DP CPE Loopback

A-1

Figure A-4. FT1 Repeater Network Loopback

A-2

Figure A-5. FNID Network Loopback

A-2

Figure A-6. FNID CPE Loopback

A-2

 

 

Tables

 

Table A.

LED Indications

3

Table B. FT1 Repeater Apparatus Cases

3

Table C. Loop Insertion Loss Data

4

Table D. HDSL FT1 Repeater Unit Specifications

6

Table A-1. FT1 Loopback Select Codes

A-3

1. GENERAL

This practice provides installation and maintenance procedures for the ADTRAN Single-Wide Fractional T1 (FT1) Repeater, (ADTRAN P/N 1245211L1), illustrated in Figure 1.

The ADTRAN Single-Wide FT1 Repeater is a device used to extend the effective range of an ADTRAN FT1 circuit. It is capable of doubling the deployment range of standard HDSL, providing a carrier service area (CSA) compliant loop on both sides of the Single-Wide FT1 Repeater.

1

GND

 

 

2

NC

 

 

3

T

CUSTOMER

 

4

R

LOOP 1

 

 

 

5

T

NETWORK

FT1 REPEATER

6

R

LOOP 1

7

NC

1245211L1

8

NC

9

NC

10

GND

11

NC

12

NC

 

 

Figure 1. ADTRAN Single-Wide FT1 Repeater

Features of the Single-Wide FT1 Repeater include:

¥2B1Q line coding

¥Range up to 12 kft of 24-gauge wire each direction from FT1 Repeater

¥Lightning protection

¥Remote loopback control

¥Coexists with DDS and ISDN repeaters in same apparatus case

¥Remote performance monitoring capability

This unit is used in conjunction with any span powering FT1 DP for the central office and span powered FNID remote end as follows:

Part Number

Unit Name

1245206L1

Siemens FT1 DP

1245207L1

Northern Telecom FT1 DP

1245208L1

ALCATEL FT1 DP

1245205L1

WECO D4 FT1 DP

1245201L1

FNID (T400)

1242046L2

Siemens FT1 DP

1242047L2

Northern Telecom FT1 DP

1242048L2

Alcatel FT1 DP

1242040L2

AT&T FT1 DP

1242041L2

FNID (T400)

1242042L2

FNID (standalone)

The ADTRAN Single-Wide FT1 Repeater provides a means of extending the digital subscriber loop serving range using a centrally-located unit. There are no manual option settings on the Single-Wide FT1 Repeater.

61245211L1-5A

Trademarks:

Any brand names and product names included in this document are

1

 

trademarks,

registered trademarks, or trade names of their respective holders.

 

Image 1
Contents General Issue 1, DecemberL1-5 Clei Code # T1R6GMJDAADescription and Indications Table A. LED IndicationsRevision History InstallationTable B. FT1 Repeater Apparatus Cases PartReplacement of Circuit Packs MaintenanceTesting the FT1 Repeater at the CO FT1 Repeater LoopbacksTable C. Loop Insertion Loss Data CSA Deployment GuidelinesFrequency Maximum Loss Warranty and Customer Service SpecificationsAdtran Customer Service Table D. Hdsl FT1 Repeater Unit SpecificationsFigure A-1. FT1 Loopbacks FT1 LoopbacksFigure A-4. FT1 Repeater Network Loopback Table A-1. FT1 Loopback Select Codes Loopback Activation and DeactivationLoopback Select FT1 Device Code Name Code Byte LOOP-UP State