ADTRAN FT1 specifications Specifications, Warranty and Customer Service, Adtran Customer Service

Page 6

6. SPECIFICATIONS

Specifications for the ADTRAN Single-Wide FT1 Repeater appear in Table D.

7. WARRANTY AND CUSTOMER SERVICE

ADTRAN will replace or repair this product within ten years from the date of shipment if it does not meet its published specifications or fails while in service (see ADTRAN Equipment Warranty, Repair, and Return Policy and Procedure).

Return Material Authorization (RMA) is required prior to returning equipment to ADTRAN.

For service, RMA requests, or further information, contact one of the following numbers.

ADTRAN Customer Service

ADTRAN Telco Technical Support . (800) 726-8663

Standard support hours

..................... Monday-Friday

 

7 a.m. - 7 p.m. CST

Emergency support

7 days/week, 24 hours/day

Sales

(800) 827-0807

RMA (repair service)

(256) 963-8722

Repair and Return Address

ADTRAN, Inc.

Customer and Product Support (CAPS) Department

901 Explorer Boulevard

Huntsville, Alabama 35806-2807

Table D. HDSL FT1 Repeater Unit Specifications

Loop Interface

 

 

Modulation Type

2B1Q

 

Mode

Full Duplex, Echo Cancelling

Number of Pairs

One

 

Bit Rate

784 kbps per pair

 

Baud Rate

392K baud per pair

 

Service Range

Defined by Carrier Service Area Guidelines

Loop Loss

35.25 dB maximum @ 200 kHz

Bridged Taps

Single Taps < 2 kft, Total Taps < 2.5 kft

Performance

Compliant with Bellcore TA-NWT-001210

Return Loss

20 dB (40 kHz to 200 kHz)

 

HDSL Tx Signal Level

13.5 dBm

 

Input Impedance

135 Ω

 

Power

 

 

Input Power

(span-powered by FT1 DP) 3 W maximum

Tests

 

 

Diagnostics

Loopback initiated with DDS latching loopback codes.

 

Self test initiated from FT1-DP or FNID.

Physical

 

 

Dimensions

6.36" long, 2.60" high, 0.7" deep

Weight

12 ounces

 

Environment

 

-40°C to +50°C

Temperature

Operating (Standard)

 

Storage

-40°C to +85°C

Part Number

ADTRAN Single-Wide FT1 Repeater 1245211L1

6

Section 61245211L1-5, Issue 1

61245211L1-5A

Image 6
Contents L1-5 Issue 1, DecemberGeneral Clei Code # T1R6GMJDAATable A. LED Indications Description and Indications Table B. FT1 Repeater Apparatus Cases Installation Revision History PartTesting the FT1 Repeater at the CO MaintenanceReplacement of Circuit Packs FT1 Repeater LoopbacksCSA Deployment Guidelines Table C. Loop Insertion Loss DataFrequency Maximum Loss Adtran Customer Service SpecificationsWarranty and Customer Service Table D. Hdsl FT1 Repeater Unit SpecificationsFT1 Loopbacks Figure A-1. FT1 LoopbacksFigure A-4. FT1 Repeater Network Loopback Loopback Activation and Deactivation Table A-1. FT1 Loopback Select CodesLoopback Select FT1 Device Code Name Code Byte LOOP-UP State