ADTRAN Revision History, Installation, Table B. FT1 Repeater Apparatus Cases, Part

Page 3

The connector pinout for the Single-Wide FT1 Repeater is shown in Figure 2.

1

GND

2

NC

 

3

T

CUSTOMER

4

R

LOOP 1

5

T

NETWORK

6

R

LOOP 1

7

NC

 

8

NC

 

9

NC

 

10

GND

11

NC

 

12

NC

 

Figure 2. ADTRAN Single-Wide FT1 Repeater

Connector Pinout

Revision History

This is the first issue of this practice. In subsequent issues, revisions will be summarized in this paragraph.

2. INSTALLATION

CAUTION

This equipment contains static-sensitive components. Be sure to follow proper electrostatic discharge procedures before handling or installing the equipment.

The Single-Wide FT1 Repeater circuit pack is shipped in a separate carton and must be installed in an environmental apparatus case.

Remove the Single-Wide FT1 Repeater circuit pack from the carton and visually ensure that damage has not occurred during shipping or handling. If damage has occurred, file a claim immediately with the carrier, then contact ADTRAN customer service.

The Single-Wide FT1 Repeater circuit pack is designed for installation in a pre-wired apparatus case. These are described in Table B.

Table B. FT1 Repeater Apparatus Cases

ADTRAN

 

 

Part

 

FT1

Number

Description

Repeaters

1150027L1 ...

4-Slot, Dual T1 form, air

........ 4

1150027L2 ...

4-slot, Dual T1 form, gel

........ 4

1152010L3 ...

2-slot, Dual T1 form, gel

........ 2

1152010L4 ...

2-slot, Dual T1 form, air

......... 2

1150057L1 ...

4-slot, Universal, air

4

1150057L2 ...

4-slot, Universal, gel

4

1150058L1 ...

8-slot, Universal, air

6

1150058L2 ...

8-slot, Universal, gel

6

3.INSTALLATION OF SINGLE-WIDE FT1 REPEATERS IN ADTRAN APPARATUS CASES

When installing the Single-Wide FT1 Repeater in an ADTRAN apparatus case, refer to the ADTRAN Installation/Maintenance practice for the apparatus case being used.

CAUTION

The housing must be considered to be under pressure and should be handled accordingly. The Single-Wide FT1 Repeater dissipates a maximum of 3 watts.

61245211L1-5A

Section 61245211L1-5, Issue 1

3

Image 3
Contents Clei Code # T1R6GMJDAA Issue 1, DecemberGeneral L1-5Description and Indications Table A. LED IndicationsPart InstallationRevision History Table B. FT1 Repeater Apparatus CasesFT1 Repeater Loopbacks MaintenanceReplacement of Circuit Packs Testing the FT1 Repeater at the COCSA Deployment Guidelines Table C. Loop Insertion Loss DataFrequency Maximum Loss Table D. Hdsl FT1 Repeater Unit Specifications SpecificationsWarranty and Customer Service Adtran Customer ServiceFigure A-1. FT1 Loopbacks FT1 LoopbacksFigure A-4. FT1 Repeater Network Loopback Loopback Activation and Deactivation Table A-1. FT1 Loopback Select CodesLoopback Select FT1 Device Code Name Code Byte LOOP-UP State