ADTRAN T200 FNID specifications L1-5C Issue 3, September Clei Code NCDIFBH4, Revision History

Page 1

Section 61245201L1-5C

Issue 3, September 1999

CLEI Code: NCDIFBH4 _ _

FNID and T200 FNID

Fractional T1 Network Interface Device

Installation and Maintenance

CONTENTS

 

1.

GENERAL

1

2.

INSTALLATION

2

3.

CONNECTIONS

3

4.

DSL SYSTEM TESTING

4

5.

CONTROL PORT OPERATION

4

6.

DSL DEPLOYMENT GUIDELINES

11

7.

TROUBLESHOOTING PROCEDURES

12

8.

MAINTENANCE

12

9.

PRODUCT SPECIFICATIONS

12

10. WARRANTY AND CUSTOMER SERVICE

12

Appendix A. FT1 Loopbacks

A-1

FIGURES

 

 

Figure 1.

ADTRAN FNID

1

Figure 2. FNID Option Switch Locations

2

Figure 3. FNID Network Loop Connection Locations

4

Figure 4. RS-232 (DB9) Pin Assignments

4

Figure 5. Introductory Menu Screen

7

Figure 6. HDSL Main Menu Screen

7

Figure 7. Current System Status Screen

8

Figure 8. Performance History Screen

8

Figure 9. Loopback Options Screen

9

Figure 10. Self Test Options Screen

9

Figure 11. Provisioning Options Screen

10

Figure 12.

Troubleshooting Screen

10

Figure 13. DSL Deployment Guidelines

11

Figure A-1.

FT1 Loopbacks

A-1

Figure A-2. FT1 DP Network Loopback

A-1

Figure A-3. FT1 DP CPE Loopback

A-1

Figure A-4. FT1 Repeater #1 or # 2 Network Loopback

A-2

Figure A-5. FNID Network Loopback

A-2

Figure A-6. FNID CPE Loopback

A-2

TABLES

 

 

Table A. Front Panel Functions

3

Table B.

FNID Card Edge Pin Definitions

3

Table C.

Definition of Screen Abbreviations

5

Table D. Loop Insertion Loss Data

11

Table E.

Troubleshooting Guide

12

Table F.

FNID Unit Specifications

13

Table A-1.

FT1 Loopback Select Codes

A-3

 

FNID

1245201L1

 

 

DSL

 

 

DS1

ESF

SF

(YEL)

(GRN)

B8ZS

AMI

(YEL)

(GRN)

 

 

 

 

LBK

L

LOC

 

B

 

K

 

 

 

REM

M

TX

 

O

 

 

N

RX

 

 

 

R

 

 

S

 

 

2

 

 

3

 

 

2

 

 

Figure 1. ADTRAN FNID

1. General

This practice is an installation and maintenance (I/M) guide for the ADTRAN Fractional T1 Network Interface Device (FNID). Figure 1 is an illustration of the ADTRAN FNID.

Revision History

This practice has been reissued to reflect additional support detail for two FT1 repeater applications.

The ADTRAN FNID is a network terminating unit used to deploy a fractional T1 circuit using 2-wire metallic facilities on CSA loops. This practice is written to support both the T200 FNID circuit pack (P/NÊ1245201L1) and the FNID standalone

(P/NÊ4245201L1) units.

The FNID is housed in a standalone metal enclosure. The T200 FNID card plugs into a standard Type 200/400 multiple mounting shelf.

61245201L1-5C

Trademarks: Any brand names and product names included in this document are

1

 

trademarks, registered trademarks, or trade names of their respective holders.

 

Image 1
Contents Revision History L1-5C Issue 3, September Clei Code NCDIFBH4Fnid Option Switch Locations InstallationTable A. Front Panel Functions Indicator DescriptionConnections Table B. Fnid Card Edge Pin DefinitionsControl Port Operation DSL System TestingDS1 MON Bantam Jack Fnid LoopbacksAbbreviation Definition Table C. Definition of Screen AbbreviationsL1-5, Issue 61245201L1-5C Introductory Menu Screen Current System Status Screen Loopback Options Screen Provisioning Options Screen Table D. Loop Insertion Loss Data DSL Deployment GuidelinesFrequency Hz Maximum Loss dB Maintenance Troubleshooting ProceduresProduct Specifications Warranty and Customer ServiceTable F. Fnid Unit Specifications Appendix a FT1 Loopbacks Figure A-4. FT1 Repeater # 1 or 2 Network Loopback FT1 DP FT1 Device Loopback Select Code Name Code Byte