7.TROUBLESHOOTING PROCEDURES

Table E is a troubleshooting guide for the FNID.

8.MAINTENANCE

The ADTRAN FNID requires no routine maintenance. In case of equipment malfunction, use the faceplate Bantam jack connectors to help locate the source of the problem.

ADTRAN does not recommend that repairs be performed in the field. Repair services may be obtained by returning the defective unit to the ADTRAN Customer Service RMA Department.

9.PRODUCT SPECIFICATIONS

Specifications for the FNID are provided in Table F.

10.WARRANTY AND CUSTOMER SERVICE

ADTRAN will replace or repair this product within five years from the date of shipment, if the product does not meet its published specifications or if it fails while in service. For detailed warranty, repair, and return information, refer to the ADTRAN Telco Network Equipment Warranty and Return Policy and Procedure, document 6000008-10A.

Return Material Authorization (RMA) is required prior to returning equipment to ADTRAN. ADTRAN does not recommend that repairs be performed in the field.

For service, RMA requests, or further information, contact one of the following numbers:

ADTRAN Customer Service:

ADTRAN Telco Technical Support . (800) 726-8663

Standard support hours

..................... Monday-Friday

 

7 a.m. -

7 p.m. CST

Emergency support

7 days/week, 24 hours/day

Sales

(800)

827-0807

RMA (repair service)

(256)

963-8722

Repair and Return Address:

ADTRAN, Inc.

Customer and Product Support (CAPS) Department

901 Explorer Boulevard

Huntsville, Alabama 35806-2807

 

 

Table E. Troubleshooting Guide

 

 

Condition

Solution

 

 

 

All front panel indicators are off.

1.

Verify that the FNID is properly seated in the housing.

 

2.

Make sure power supply feed the FNID is in good working condition.

 

3.

If Steps 1 and 2 pass, replace the FNID.

Power is OK, but does not achieve

1.

Verify that the loop conforms with CSA guidelines (not too long, etc.).

loop sync (DSL LED is off.)

2.

Verify that the loop loss at 200 kHz is not greater than 36 dB.

 

3.

Verify that noise on the DSL loop is within acceptable limits.

 

4.

If Steps 1 through 4 pass and loop sync is still not available, replace the FNID.

 

 

 

12

Section 61245201L1-5, Issue 3

61245201L1-5C

Image 12
Contents L1-5C Issue 3, September Clei Code NCDIFBH4 Revision HistoryInstallation Fnid Option Switch LocationsIndicator Description Table A. Front Panel FunctionsConnections Table B. Fnid Card Edge Pin DefinitionsDSL System Testing Control Port OperationDS1 MON Bantam Jack Fnid LoopbacksTable C. Definition of Screen Abbreviations Abbreviation DefinitionL1-5, Issue 61245201L1-5C Introductory Menu Screen Current System Status Screen Loopback Options Screen Provisioning Options Screen DSL Deployment Guidelines Table D. Loop Insertion Loss DataFrequency Hz Maximum Loss dB Troubleshooting Procedures MaintenanceProduct Specifications Warranty and Customer ServiceTable F. Fnid Unit Specifications Appendix a FT1 Loopbacks Figure A-4. FT1 Repeater # 1 or 2 Network Loopback FT1 Device Loopback Select Code Name Code Byte FT1 DP