ADTRAN T200 FNID specifications DSL Deployment Guidelines, Table D. Loop Insertion Loss Data

Page 11

6. DSL DEPLOYMENT GUIDELINES

The ADTRAN FT1 DSL system is designed to provide Fractional DS1-based services over loops designed to comply with Carrier Service Area (CSA) guidelines. CSA deployment guidelines are given below.

1. All loops are non-loaded only.

2.For loops with 26-AWG cable, the maximum loop length including bridged tap lengths is 9 kft.

3.For loops with 24-AWG cable, the maximum loop length including bridged tap lengths is 12 kft.

4.Any single bridged tap is limited to 2 kft.

5.Total bridged tap length is limited to 2.5 kft.

6.The total length of multi-gauge cable containing 26-AWG cable must not exceed 12Ê-Ê{(3*L26)/9}Ê-ÊLBTAP(inÊkft)

L26

=

Total length of 26-AWG cable

 

 

excluding bridged taps (in kft)

LBTAP

=

Total length of all bridged taps (inÊkft)

This deployment criteria is summarized in the chart shown in Figure 13.

 

12

 

 

 

 

 

 

 

 

 

(KFT)

11

 

 

INVALID DSL CABLE LENGTHS

 

 

 

 

 

 

 

10

 

 

 

 

 

 

 

 

 

CABLE

 

 

 

 

 

 

 

 

 

9

 

 

 

 

TOTAL

 

 

 

 

COARSER)

 

 

 

 

BRIDGED

 

 

 

 

 

 

2.5

 

 

 

 

 

 

 

TAP

 

 

8

 

 

 

2.0

 

 

 

 

 

 

1.5

 

LENGTH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.0

0.5

(KFT)

 

 

 

 

 

 

 

 

 

 

7

 

 

 

 

 

 

0.0

 

 

(OR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GAUGE

6

 

 

 

 

 

 

 

 

 

5

 

 

 

 

 

 

 

 

 

OF 24

 

 

 

 

 

 

 

 

 

4

 

 

 

 

 

 

 

 

 

LENGTH

 

 

 

 

 

 

 

 

 

3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WORKING

2

 

 

 

 

 

 

 

 

 

1

VALID DSL CABLE LENGTHS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

 

 

 

 

 

 

 

 

 

0

1

2

3

4

5

6

7

8

9

 

 

WORKING LENGTH OF 26 GAUGE CABLE (KFT)

 

Figure 13. DSL Deployment Guidelines

Recommended maximum local loop loss information for PIC cable at 70°F, 135Ω, resistive termination is provided in Table D.

Table D. Loop Insertion Loss Data

Frequency (Hz)

Maximum Loss (dB)

 

 

3,000

12.0

10,000

15.0

50,000

25.5

100,000

30.0

150,000

32.75

200,000

35.25

 

 

An approximation for the maximum amount of wideband noise on a DSL local loop as measured by a 50 kbps filter is ≤ 31 dBrn.

An approximation for the maximum level of impulse noise as measured using a 50 kbps filter on an DSL loop is ≤ 50 dBrn.

These approximations are to be used as guidelines only and may vary slightly on different loops. Adhering to the guidelines should produce performance in excess of 10-7ÊBER.

61245201L1-5C

Section 61245201L1-5, Issue 3

11

Image 11
Contents Revision History L1-5C Issue 3, September Clei Code NCDIFBH4Fnid Option Switch Locations InstallationTable B. Fnid Card Edge Pin Definitions Indicator DescriptionTable A. Front Panel Functions ConnectionsFnid Loopbacks DSL System TestingControl Port Operation DS1 MON Bantam JackAbbreviation Definition Table C. Definition of Screen AbbreviationsL1-5, Issue 61245201L1-5C Introductory Menu Screen Current System Status Screen Loopback Options Screen Provisioning Options Screen Frequency Hz Maximum Loss dB DSL Deployment GuidelinesTable D. Loop Insertion Loss Data Warranty and Customer Service Troubleshooting ProceduresMaintenance Product SpecificationsTable F. Fnid Unit Specifications Appendix a FT1 Loopbacks Figure A-4. FT1 Repeater # 1 or 2 Network Loopback FT1 DP FT1 Device Loopback Select Code Name Code Byte