3Com 5104M-FL1 installation and operation guide Determining Link Budget

Page 29

Determining Link Budget

As a network planner or installer, account for worst case losses through the optical connection, end-to-end, to ensure link integrity. The optical power budget represents a “worst case” assuming the transmitter is transmitting at the low end of its range.

Adhere to the IEEE 802.3 10BASE-FL specification which states that the minimum distance supported between two 10BASE-FL ports is 2 kilometers.

If the link between two 10BASE-FL ports is:

Less than 2 kilometers and contains minimal losses (that is, only one splice or connector and typical fiber cable attenuation) you do not need to calculate the optical budget for the link.

If you must exceed 2 kilometers, or if you have multiple splices in the cable, you must calculate the optical power budget.

Note: When connecting a 10BASE-FL product to an FOIRL product, do not exceed the 1 kilometer maximum distance defined by the 802.3 FOIRL specification. Because 10BASE-FL is backward compatible with FOIRL, you can make mixed 10BASE-FL/FOIRL connections. However, to interoperate 10BASE-FL and FOIRL equipment, observe the more limiting restrictions of the FOIRL specification.

Table 2-3 provides the Transmit Optical Power ranges and required Receiver Optical Power sensitivity levels for the 10BASE-FL Module.

Designing and Expanding the Network 2 - 7

Image 29
Contents Page Vcci Class 1 Compliance Page Page Contents Installing and Operating the Module Appendix a Specifications Page Figures Page Tables Page Audience How to Use This GuideStructure of This Guide Text Convention Example Document ConventionsText Conventions 3Com Documents Related DocumentsReference Documents Page Introduction 10BASE-FL Module Description Theory of Operation 10BASE-FL and Foirl Ieee Standards ComparisonBASE-F Standards 10BASE-F Standard DescriptionBASE-FL Module Connections Designing and ExpandingtheNetwork Basic Network Rules Understanding the General RulesSeven Basic Network Rules Rule Definition Recommendations/NotesAs equivalent distance. Every Assume that one LAN Product Equivalent LAN EquivalenceLAN Product Equivalent Distances Calculating Maximum Link Distance Determining Maximum 10BASE-FL Link DistancesDetermining Link Budget Cable Size Transmit Receive Optical Link Loss Power BASE-FL Module Optical Power BudgetDBm ONline toSplicing Connector Type Range of Loss Per Typical Loss dB Pair dB Connector and Splice Insertion LossTypical Fiber Loss Characteristics Splice Type Range of Loss dB Typical Loss dBMeter Fiber Link With Mechanical Splice Example Fiber Link With Mechanical SpliceMeter Fiber Link Through Two Patch Panels Example Fiber Link Through Patch PanelsChoosing a Network Backbone Cabling Structure Star ConfigurationStar-Wiring Configuration Serial ConfigurationSerial Configuration Using 10BASE-FL Modules 10BASE-FL Module Configurations10BASE-FL Backbone, 10BASE-FL to-the-Desk All-10BASE-FL Network with 3 Concentrators Example a Network with 6 Concentrators Example a Network with 3 ConcentratorsNetwork with 6 Concentrators Fiber Equivalent Distances Between Transceivers 10BASE-FL Backbone, Unshielded Twisted Pair to-the-DeskTotal Fiber Number Equivalent PathExample Sample Configuration Distance Calculation Sample Configuration Distance Calculation 10BASE-FB Fiber Backbone, 10BASE-FL to-the-Desk Example Fiber Backbone, 10BASE-FL to-the-Desk Sample Fiber Backbone, 10BASE-FL to-the-Desk ConfigurationConnecting External Network Devices Ieee Example Connecting a Thin Ethernet 10BASE2 SegmentDesigning and Expanding the Network 2 Standard Redundant Configuration In this configuration Fault-Tolerant ConfigurationsConfiguring Ports for Fault Tolerance Setting Redundancy Implementing Backbone Cable Plant Fault Tolerance10. Redundant Fiber Backbone Configuration Remote Failure Signaling 11. Total Backbone Fault-Tolerant Configuration Implementing Total Backbone Fault Tolerance12. Network With 3 Concentrators ONline Ethernet 10BASE-FL Installation and Operation Guide Installing and Operating the Module Unpacking Procedures Precautionary ProceduresStep Procedure Section Title Quick InstallationQuick Installation Procedures Setting the Dip Switches BASE-FL Module Dip Switch Locations Setting Dip Switch SW1Function Off Default Dip Switch SW1 SettingsFactory Switch Setting Switch Function Factory Default Setting Dip Switch SW2Dip Switch SW2 Settings for Switches 1 to Dip Switch SW2 Settings for Switches 5 Installing the ModuleSwitch Settings Channel SelectionInstalling the 10BASE-FL Module BASE-FL Module Connection Configuring the Module Enabling Ports Enabling Port Redundancy Selecting a NetworkSET Port slot.port Mode Redundant slot.port BASE-FL Modules Connected with Redundancy/RFS Enabled Enabling Remote Failure SignalingSaving Module Configuration Showing Module ConfigurationMonitoring the Front Panel Shows the location of these indicatorsBASE-FL Module Faceplate and ONline System Concentrator LED Name Color State Indicates Interpreting the 10BASE-FL Module LEDsNetwork Check Codes LED State Module Is Configured forVerifying the LED and Network Assignments Troubleshooting Troubleshooting Using the Port Activity LEDs Troubleshooting Using the Port Activity LEDsLED Name Possible Cause Corrective Action StateLED State Indication Possible Cause Corrective Action Troubleshooting Using the Port Status LEDsTroubleshooting Using the Port Status LEDs Replace remote device Technical Assistance RFS TroubleshootingONline Ethernet 10BASE-FL Installation and Operation Guide Specifications Table A-1. General Specifications General SpecificationsTable A-2. Transmit Power Peak Values Optical SpecificationsTransmitter Specifications Supported Fiber Optic Cables Receiver SpecificationsTable A-3. Receiver Specifications Table A-4. Fiber Optic Interface Specifications Power RequirementsTable A-5. Power Requirements Fiber Optic InterfaceMechanical Specifications Environmental SpecificationsTable A-6. Electrical Specifications Table A-7. Mechanical SpecificationsFiber Cables and Connectors 10BASE-FL Cable and Connector SpecificationsConnector Type Part Number Table A-8. Connector Type Part NumberOn-line Technical Support Technical SupportWorld Wide Web Site Support from Your Network SupplierEmail Technical Support Support from 3Com Returning Products for Repair Accessing the 3Com MIB3Com Technical Publications Page Index Index RFS VDE compliance Verify LED Operation, 3-19Network Assignment