2. Overview

The ACT-IR100S-L/LM is a IrDA-Ready intelligent adapter. This enables the host system with IrDA communication capabilities. The host system may be a serial printer, a modem, an industrial controller, a data collector, a medical instrument, or any other device, that may benefit from being IrDA enabled.

The interface between ACT-IR100S-L/LM and the host is via a traditional asynchronous serial data port (RS232C). Figure 2.1 shows the system block diagram.

Figure 2.1 System Block Diagram

 

 

 

ACT-IR100S-L

 

 

 

75LV4737

 

IR8200IC

IR220VACF

 

 

 

 

 

 

TXD

/TXD

/TXD1

/RXD0

/RXDO

/RXDI

 

RXD

/RXD

/RXD1

/TXD0

/TXDI

TXDO

 

 

 

 

 

 

Optical

RS232C

 

 

/RTS1

/RTS0

/MODE

Transceiver

 

RTS

/RTS1

/DTR0

/RESET

 

 

CTS

/CTS1

/CTS1

 

 

 

 

DSR

/DSR1

/DSR1

 

EEPROM

 

DTR

/DTR1

/DTR1

 

 

CD

/CD1

/CD1

 

 

 

 

RI

/RI1

/RI1

SEL0

 

 

 

 

 

 

SEL1

 

 

 

 

 

 

SEL2

 

 

 

 

 

 

:

 

 

 

 

 

 

:

Jumpers for Host

 

 

 

 

 

baud rate setting

 

 

 

 

 

and flow control

 

 

 

 

 

etc.

- 6 -

Version 1.20

 

May 27, 2002

Image 7 Contents
ACT-IR100SL-M ACT-IR100SL and IR100SL-M User’s Manual Limited Warranty Precautions Features ACT-IR100SL and IR100SL-M User’s Manual ACT-IR100S-L OverviewSIR IrPHY encoder-decoder Applications Embedded IrDA protocol stackACT-IR8200IC-L Blinking LED Baud Rate Setting Ignore CTS Ignore DSREnable Eeprom Function DisableACT-IR100SL and IR100SL-M User’s Manual Pin No Name Descriptions RS-232C DTE DB-9P ConnectorHow to Connect IR100S-L/LM with host Device DTE 220L/L+ IrDA Com-Port Serial Adapter ACT-1 IrDA Primary Station Protocol StackII ACT-2 IrDA Secondary Station Protocol Stack 100M IrDA Printer AdapterLimited Warranty Corporation