ACTiSYS IR100SLM user manual Ignore DSR, Ignore CTS

Page 12

ACT-IR100SL and IR100SL-M User’s Manual

4.3 Ignore DSR

SEL3 open(SEL3=1) means ignore the physical DSR input, pretend that DSR is on. This logical DSR is always used for connection control.

The physical DTR is used for connection indication. SEL3 has no effect on DTR.

When SEL3 close(SEL3=0), DSR is used for connection control. Active DSR permits IrDA connection. Inactive DSR forbids new connection and terminates existing connection.

 

 

Jumper

 

 

Ignore DSR

SEL3

Descriptions

 

NO

0

DSR is used for IR connection control.

 

YES

1

Ignore DSR input.

 

 

 

 

4.4 Ignore CTS

 

 

SEL4 open(SEL4=1) means ignore the Physical CTS input, pretend that CTS is on. This logical CTS is always used for TXD flow-control.

The physical RTS is used for RXD flow-control. SEL4 has no effect on RTS.

When SEL4 close(SEL4=0), CTS is used for flow control of TXD. Active CTS permits TXD. Inactive CTS forbids TXD.

 

Jumper

 

Ignore CTS

SEL4

Descriptions

NO

0

CTS is used for RxD flow control.

YES

1

Ignore CTS input.

 

 

 

- 11 -

Version 1.20

 

May 27, 2002

Image 12
Contents ACT-IR100SL-M ACT-IR100SL and IR100SL-M User’s Manual Limited Warranty Precautions Features ACT-IR100SL and IR100SL-M User’s Manual Overview ACT-IR100S-LApplications Embedded IrDA protocol stack SIR IrPHY encoder-decoderACT-IR8200IC-L Blinking LED Baud Rate Setting Ignore DSR Ignore CTSEeprom Function Disable EnableACT-IR100SL and IR100SL-M User’s Manual RS-232C DTE DB-9P Connector Pin No Name DescriptionsHow to Connect IR100S-L/LM with host Device DTE ACT-1 IrDA Primary Station Protocol Stack II ACT-2 IrDA Secondary Station Protocol Stack100M IrDA Printer Adapter 220L/L+ IrDA Com-Port Serial AdapterLimited Warranty Corporation