Chauvet ART-575W AC C Essing I NT ERN AL Prog R AM S in Mast ER M ODE, PIN # 4= PIN # 2= Total =

Page 11

Operating Instructions

AC C ESSING I NT ERN AL PROG R AM S IN MAST ER M ODE

The programs are available while the fixture is set to the Master mode which is dipswitch 11 to ON and 12 to OFF. The programs are assigned to the first 42 channels or numerical values which can be initialized using the dipswitches.

Each dipswitch has an associated value. These values are not printed on the fixture so it is very important that you read this section thoroughly. Adding the value of each switch in the ON position will provide the channel address. Determining which switches to toggle ON given a specific channel address can be accomplished in the following manner. By subtracting the largest switch value possible from the selected channel address which does not cause a negative number.

This is the exact method for computing DMX address values as well and this section will be repeated.

EXAMPLE CHANNEL ADDRESS

CHANNEL 10

PIN # 4= 8

PIN # 2= 2

TOTAL = 10

CHANNEL 24

PIN # 5= 16

PIN # 4= 8

TOTAL= 24

 

 

 

THE CHANNEL ADDRESSES WERE SELECTED AT RANDOM.

ON

 

 

 

 

 

 

 

 

 

1

2

3

4

5

6

7

8

9

10

11 12

1

2

4

8

16

32

64

128

256

 

Binary values

 

 

 

 

 

 

 

 

 

 

 

 

 

ON

 

 

 

 

 

 

 

 

 

1

2

3

4

5

6

7

8

9

10

11 12

1

2

4

8

16

32

64

128

256

 

Binary values

 

 

 

 

 

 

 

 

 

 

 

 

 

RESOLVING ADDRESS USING SIMPLE MATH.

ADDRESS 42

 

DIP SWITCH

 

42 (32) = 10, Turn ON Dip # 6

 

 

1

 

 

2

 

10 (8) = 2, Turn ON Dip # 4

 

3

 

2 (2) = 0, Turn ON Dip # 2

 

4

 

 

 

 

5

 

 

6

 

 

7

 

 

8

 

 

9

 

 

10

 

 

 

 

(CH VALUE)

1

2

4

8

16

32

64

128

256

The page following contains an itemized chart of the built-in programs and their associated channel address.

ART-575W User Manual

11

2006-06-15/17:08

Image 11
Contents Spectrum 575W Setup Table of ContentIs included AC PowerSafety Instructions Before YOU BeginDMX Channel Summary Technical FeaturesFeatures Introduction445.7 17.5in Product OverviewAM P I N ST ALL AT I on SetupLamp AM P AL IG NM ENT H OW T O PowerRuss M Ount ING InstallationORI ENT AT IO N Floor M Ount INGLimit one universe of DMX-512 to no more than 32 devices Between pins 2 and 3 of a male XLR connectorUse shielded twisted-pair cable designed for RS-485 devices SplitterAST ER/ SL AVE & ST AN D AL on E Operating InstructionsOperating Modes 42 32 = 10, Turn on Dip # 10 8 = 2, Turn on Dip # AC C Essing I NT ERN AL Prog R AM S in Mast ER M ODEPIN # 4= PIN # 2= Total = PIN # 5= PIN # 4=BU ILT in Prog R AM S C H ART SET T ING T H E ST ART ING AD D R ESS DM X M ODEDMX DMX Address Quick Reference Chart FI XT UR E LI NK ING AppendixDMX Primer DMX Channel Values Beampat h Photo MetricsDipswitch Location Claims MaintenanceReturns Procedure Applies to Symptom General TroubleshootingTechnical Support Technical Specifications