ADIC 2.2 manual Shared Setup, 2illustrates a shared setup

Page 30

SNFS

Shared Setup

In a shared setup, the StorNext FS server is also set up as a StorNext FS client with Fibre Channel connectivity to the SAN.

Figure 2-2illustrates a shared setup.

StorNext FS clients

TCP/IP

StorNext FS server

& StorNext FS client

Fibre Channel Switch

Storage Area Network

 

(SAN)

Disk Array

Disk Drives

Figure 2-2StorNext FS server - shared setup

2-6

6-00905-01 Rev A

Image 30
Contents StorNext File System Copyright Notice Definitions Software License Price and Payment Installation Use and Training Maintenance Term and Termination Disclaimer and Limitation of Liability General Entirety Introduction Setting Up StorNext FS on AIX Setting Up StorNext FS on Linux Resolving Installation Problems Customer Assistance Snms Introduction How This Book is Organized Explanation of Symbols # tar xvf filename Convention Example# mkdir -p mount point # chmod 777 mount pointOnline Books Related Publications Related Publications DescriptionSnfs Getting Started Topic Refer to ChapterSupported Platforms System RequirementsStorNext FS Components File DescriptionLinux Solaris Directory AIX Irix Configure File System Server Dedicated SetupShared Setup 2illustrates a shared setupUsing Optional Pre-Installation Configuration Username UserID GroupID Login Shell Home DirectoryGroup Name GroupID Members List Summary of Installation Steps Step TaskRefer to Install StorNext FS on AIX on Refer to Label Drives on AIX on Refer to Mount StorNext FS on AIX on Power Up Sequence Power Down Sequence Snfs Setting Up StorNext FS on AIX RoadmapInstallation Procedure for AIX TopicInstall StorNext FS on AIX # installp -ac -d cdrom path all# man commandname Obtain License for AIX Server # usr/cvfs/bin/cvfsid690CB94A sun 1 hostname Label Drives on AIX # /usr/cvfs/bin/cvlabel# cd /usr/cvfs/bin # ./cvlabel Configure StorNext FS Software on AIX Server ConfigurationDiskType ST318202FC Sectors SectorSize Snfs # ps -efgrep fsmpm Client Configuration Start the SystemMount StorNext FS on AIX # mkdir /usr/clipsSnfs Setting Up StorNext FS on Irix Installation Procedure for Irix Install StorNext FS on Irix IrixSet path= $path /usr/cvfs/bin # source /etc/.loginCDROM/StorNextFS/sgi/dist/dist65 mf Setenv Manpath ‘/usr/share/catman/usr/cvfs/man’Obtain License for Irix Server 690CB94A sgi 1 hostnameLabel Drives on Irix # cd /usr/cvfs/bin # ./cvlabel Configure StorNext FS Software on Irix Snfs # chkconfig cvfs on # /etc/init.d/cvfs start # cd /usr/cvfs/bin/cvmkfs filesystemname Option Description # chkconfig cvfs onMount StorNext FS on Irix Filesystemname /usr/clips cvfs rw,threads=6 0 0 whereSetting Up StorNext FS on Linux Installation Procedure for Linux Prerequisites Kernel RequirementsSuSE Linux Kernel Requirements # rpm -qi `rpm -qa grep k`# rpm -qi `rpm -qa grep gcc` # yast2 # make oldconfig # make dep bzImage modules modulesinstall Multiple LUN Support Options scsimod maxscsiluns=luns=nLUNsInstall StorNext FS on Linux # cd /mnt/cdrom/StorNextFS/linux# /etc/init.d/rawdevices restart Obtain License for Linux Server Snpc4 localhost.localdomain localhost # badE0290E3F83 linux 0 snpc4 Label Drives on Linux # /usr/cvfs/bin/cvlabel -c /usr/cvfs/config/cvlabels CvfsDisk0 sdb CvfsDisk1 sdc CvfsDisk2 sddConfigure StorNext FS Software on Linux DiskType ST31917FC Sectors SectorSizeDisk CvfsDisk12 Status UP Type ST1917FS Etc/init.d/cvfs start # cd /usr/cvfs/bin/cvmkfsprojAEnable and Start the System # /etc/init.d/cvfs restartMount StorNext FS on Linux # mkdir /usr/clips # chmod 777 /usr/clips# projA /usr/clips/ cvfs rw,threads=6 0 Setting Up StorNext FS on Solaris Installation Procedure for Solaris Install StorNext FS on Solaris # pkgadd -dcdrom pathObtain License for Solaris Server Label Drives on SolarisSnfs # cd /usr/cvfs/bin # ./cvlabel Configure StorNext FS Software on Solaris DiskType ST318202FC Sectors SectorSize # ps -ef grep fsmpm Client Configuration Mount StorNext FS on Solaris Filesystemname /usr/clips cvfs yes rw,threads=6Snfs Resolving Installation Problems Resolving Problems with AIX Verify that the File System is Active Check Error MessagesCheck Drive Connectivity Check AIX PatchesVerify the StorNext FS Setup Verify the Mounted File System Umount -t cvfs Unmount and Remount All File SystemsUnmount and Remount Specific File System Umount -at cvfsReinitialize StorNext FS Snfs Resolving Problems with Irix CvlabelCheck Irix Patches Tail -50 /var/adm/SYSLOGVerify the StorNext FS Setup Remount all StorNext File Systems on a client Reinitialize StorNext FS Snfs Resolving Problems on Linux Enter show long Verify File System is ActiveCheck Linux Patches Tail -50 /var/adm/messagesVerify the StorNext FS Setup Unmount and Remount the File System Etc/rc.d/init.d/cvfs stopReinitialize StorNext FS Resolving Problems on Solaris Check Solaris Patches Verify the StorNext FS Setup Umount -F cvfs Umount -a -F cvfsReinitialize StorNext FS Snfs Snfs Customer Assistance Snfs Glossary Unmanaged file system AIX Irix Snfs Snfs
Related manuals
Manual 4 pages 39.43 Kb