Emerson WEB/485 quick start Web Support, Snmp Support, Modbus Support Liebert Nform Support

Page 2

User Manual

This guide is designed to give you the information you need to install and configure the Liebert IntelliSlot Web/485 card with adapter. A full user manual, SL-52615, is available online at www.liebert.com. Emerson Network Power highly recommends that new users consult the user manual.

Web Support

The Liebert IntelliSlot Web/485 card with adapter delivers Web management and control to Liebert equipment. All users on your network will be able to view status information. Control and configuration capabilities are protected by a username and password combination. The default username is “Liebert” and the default password is also “Liebert.”

You can change the password from the Web or from the service terminal.

NOTE: Change the username and password today to prevent unauthorized access.

SNMP Support

The Liebert IntelliSlot Web/485 card with adapter enables SNMP management of Liebert equipment.

To integrate the card into your SNMP implementation, you will need to compile the Liebert Global Products MIB on your network management station (NMS).

The Liebert Global Products MIB, which supports both Windows and Unix file formats, is included in this package on CD-ROM or may be

downloaded at www.liebert.com.

ModbusSupport

Building Management Systems play a vital role in the overall operations of facilities and buildings. Most building management systems provide device communications via the Modbus protocol. The IntelliSlot Web/485 card with adapter provides a Modbus interface to Liebert equipment, enabling integration with your building management system. Product details are available online at www.liebert.com.

Liebert NformSupport

Utilizing the SNMP and Web technologies built into each Liebert IntelliSlot Web/485 card with adapter, Liebert Nform will centrally manage alarm notifications to provide you with an easy interface to access critical system information. A downloadable edition is available online at nform.liebert.com.

Liebert MultiLinkSupport

The card installed in a UPS may be used with Liebert MultiLink software, providing unattended, graceful operating system shutdown. The card can be monitored by Liebert MultiLink over a network, eliminating the need for serial cables. Downloadable versions of Liebert MultiLink and product details are available online at multilink.liebert.com.

Locations

United States

1050 Dearborn Drive

P.O. Box 29186

Columbus, OH 43229

Europe

Via Leonardo Da Vinci 8 Zona Industriale Tognana 35028 Piove Di Sacco (PD) Italy +39 049 9719 111

Fax: +39 049 5841 257

Asia

7/F Dah Sing Financial Centre 108 Gloucester Road, Wanchai Hong Kong

852 2572 2201 Fax: 852 2519 9210

SL-29107_REV01_02-09

Technical Support/Service

Web Site

www.liebert.com

Monitoring 800-222-5877 Liebert.monitoring@emerson.com Outside the US: 614-841-6755

© 2008 Liebert Corporation

All rights reserved throughout the world. Specifications subject to change without notice.

®Liebert is a registered trademark of Liebert Corporation. All names referred to are trademarks or registered trademarks of their respective owners.

Image 2
Contents Connect the Cable InstallConfigure the Card DB-9 Port MAC AddressModbus Support Liebert Nform Support Web SupportSnmp Support Liebert MultiLink Support
Related manuals
Manual 2 pages 85 b

WEB/485 specifications

The Emerson WEB/485 is a powerful and versatile web-server designed for the continuous monitoring and management of industrial automation systems. As a robust device, it facilitates communication between various field devices, such as sensors, controllers, and data acquisition systems, and provides users with remote access to these systems through standard web protocols.

One of the standout features of the WEB/485 is its capability to support multiple communication protocols. It is compatible with MODBUS RTU, MODBUS TCP/IP, and several others, making it an ideal solution for integrating legacy systems with modern technologies. This flexibility allows users to harness the full potential of their existing infrastructure without the need for costly and extensive upgrades.

The WEB/485 is equipped with an Ethernet port along with RS-232/RS-485 serial interfaces, enabling reliable data transmission over both wired networks and point-to-point connections. The dual communication interfaces enhance the device’s adaptability, allowing it to serve diverse environments—from factory floors to remote monitoring stations.

Security is a top priority for industrial applications, and the WEB/485 addresses this with built-in features such as user authentication and encrypted communications. This ensures that sensitive data remains secure and minimizes the risk of unauthorized access to the automation system.

Another notable characteristic of the Emerson WEB/485 is its user-friendly web interface. The device’s graphical user interface (GUI) allows operators to easily visualize real-time data, configure system settings, and generate reports without extensive training or specialized knowledge. This ease of use helps businesses improve operational efficiency as personnel can quickly respond to system alerts and anomalies.

In addition to its standard features, the WEB/485 supports customizable data logging and alarm management. Users can set up thresholds for various parameters and receive notifications via email or SMS when certain criteria are met, enabling proactive maintenance and reducing downtime.

Overall, the Emerson WEB/485 combines robust communication capabilities, security features, and user-friendly design, making it an essential tool for modern industrial automation. Its integration capabilities allow for seamless operation within a variety of systems, ultimately contributing to enhanced productivity and reliability in complex industrial environments. With its advanced functionalities, it stands out as a preferred choice for engineers and technicians aiming to optimize their automation processes.