Black Box RS-232485/422 Converter Plus, RS-232485/422 Opto-Isolator/Converter Specifications

Page 7

RS-232485/422 CONVERTERS

1. Specifications

Optical Isolation: IC109A, IC109AE, IC109C only

Interface: (1) asynchronous RS-232 port (DTE/DCE selectable); (1) asynchronous RS-485 port with improved surge protection and switch-selectable line termination or line bias

Connectors: (1) DB25 female RS-232 port; (1) four-wire terminal block (TB1) RS-485 port

Pins Supported: RS-232 port: TD, RD, RTS, CTS, CD, DTR, DSR, SG, and FG;

RS-485 port: TXA, TXB, RXA, RXB

Data Rate: Up to 115 kbps, transparent to data

Indicators: (5) LEDs: TX, RX, RTS, CD, and PWR

Temperature Tolerance: Operating: 32 to 122°F (0 to 50°C); Storage: -4 to +158°F (-20 to +70°C)

Humidity: 0 to 95% relative humidity, noncondensing

MTBF: Approximately 180,000 hours (ground benign environment)

Power: PS154 (for use with IC108A, IC109A): Input: 120 V, 60 Hz, 20W; Output: AC

17VCT, 0.7A; PS154E (for use with IC108AE, IC109AE): Input: 230 V, 50 Hz, 20W;

Output: AC 17VCT, 750 mA

Size: Standalone Unit: 1.8"H x 5.5"W x 8.5"D (4.6 x 14 x 21.6 cm);

Rackmount Card: 7.4"L x 4.7"W (18.8 x 11.9 cm); 0.6 inches thick (1.6 cm)

Weight: Standalone Unit: 1 lb. (0.5 kg); Power supply only: PS154: 0.4 lb. (0.2 kg),

PS154E: 1.1 lb. (0.5 kg)

Operation: Point to Point or Multipoint; Half or Full Duplex; Transparent to data; Selectable RTS-to-CTS delay with option to inhibit CTS if CD is present (DCE); DTE or DCE configurable RS-232 port; Normal or loopback operation

Timeout Delay: 0.15, 0.7, 2, 7, or 70 msec (for the RS-485 driver enabled by data feature)

6

Image 7
Contents IC109AE FCC and IC RFI Statements RS-232↔485/422 Converters NOM Statement Trademarks Used in this Manual Contents Specifications Specifications Introduction Jumper and Switch Configuration InstallationLayout of the Printed Circuit Board RS-232↔485/422 Converter as DCE XW1A 8-Position Shunt Driver Enabled by Data Point-to-Point DCE/DTE Configuration Function Jumper Requirements RS-232↔485/422 Converters Installation RS-232↔485/422 Converters Simplified Functional Block Diagram DTE Operation DTE Jumper Settings Installation Typical Applications Point-To-Point, 4-Wire Full- or Half-Duplex Multipoint, 4-Wire Half- or Full-Duplex Multipoint, 2-Wire Half-Duplex Sample Multipoint Operation Installation DCE DTE Appendix A. PinningPin Name Description XW1B Quick Reference User-Selectable OptionsQuick Reference USER-SELECTABLE Options Copyright 2002. Black Box Corporation. All rights reserved