Black Box ACU5114A, ACU5116A manual Radio Frequency Energy, European EMC directive 89/336/EEC

Page 25

Radio Frequency Energy

A Category 5 (or better) twisted pair cable must be used to connect the Wizard extender modules in order to maintain compliance with radio frequency energy emission regulations and ensure a suitably high level of immunity to electromagnetic disturbances.

All other interface cables used with this equipment must be shielded in order to maintain compliance with radio frequency energy emission regulations and ensure a suitably high level of immunity to electromagnetic disturbances.

European EMC directive 89/336/EEC

This equipment has been tested and found to comply with the limits for a class A computing device in accordance with the specifications in the European standard EN55022. These limits are designed to provide reasonable protection against harmful interference. This equipment generates, uses and can

radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio or television reception. However, there is no guarantee that harmful interference will not occur in a particular installation. If this equipment does cause interference to radio or television reception, which can be determined by turning the equipment on and off, the user is encouraged to correct the interference with one or more of the following measures: (a) Reorient or relocate the receiving antenna. (b) Increase the separation between the equipment and the receiver. (c) Connect the equipment to an outlet on a circuit different from that to which the receiver is connected. (d) Consult the supplier or an experienced radio/TV technician for help.

FCC Compliance Statement (United States)

This equipment generates, uses and can radiate radio frequency energy and if not installed and used properly, that is, in strict accordance with the manufacturer’s instructions, may cause interference to radio communication.

It has been tested and found to comply with the limits for a class A computing device in accordance with the specifications in Subpart B of part 15 of FCC rules, which are designed to provide reasonable protection against such interference when the equipment is operated in a commercial environment. Operation of this equipment in a residential area may cause interference, in which case the user at his own expense will be required to take whatever measures may be necessary to correct the interference. Changes or modifications not expressly approved by the manufacturer could void the user’s authority to operate the equipment.

Canadian Department of Communications RFI statement

This equipment does not exceed the class A limits for radio noise emissions from digital apparatus set out in the radio interference regulations of the Canadian Department of Communications.

Le présent appareil numérique n’émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de la classe A prescrites dans le règlement sur le brouillage radioélectriques publié par le ministère des Communications du Canada.

®

        

24

Image 25
Contents ServSwitch Wizard Extenders Contents Wizard IntroductionExtender Serial cable for RS232 connection Supplied items ACU5114A variantLocal ACU5116A module Supplied items ACU5116A variantStage a Configuration switch settings InstallationLocal module switches Local SwitchRemote Switch Remote module switchesRemote Switches 2 Stage B Mounting a module desk or rack Installation AdviceDesk mount Rack mountConnections at the Local module Stage C ConnectionsLocal keyboard, video and mouse connections Optional power connectionLocal speaker connection Power supply connection Twisted pair, power and serial connectionsConnections at the Remote module Keyboard, video and mouse connectionsTo the socket labelled Audio connections ACU5116A onlyUser arbitration and keyboard indicators Power and activity indicatorsOperation General useTo disable the video To enable the videoLocking and unlocking the system To lock the systemEntering, using and exiting configuration mode ConfigurationTo enter and use configuration mode To exit from configuration modePassword override Password settingTo set a password To override the Remote passwordWhich restore setting do I use? Microsoft and Logitech -specific mouse settingsHot plugging and mouse restoration To display a suitable high contrast image Image controls sharpness and brightnessTo use the image controls If the image controls cannot provide a crisp imageTo use skew adjustment Skew adjustmentReset all configuration options to default states Miscellaneous settingsReport firmware version Stage a Download the upgrade files Flash upgradeStage B Create a startup diskette Copy the downloaded files to the diskStage E Return all connections to their usual states Stage D Reconfigure the Remote connections and beginGetting assistance TroubleshootingNo video image is received at the Remote module On-screen mouse pointer does not respond to mouse movementsOther products in the Wizard range Safety informationEuropean EMC directive 89/336/EEC Radio Frequency EnergyFCC Compliance Statement United States Certification notice for equipment used in Canada Instrucciones de seguridad Normas Oficiales Mexicanas NOM electrical safety statementCountry Web Site/Email Phone Fax BlackBox subsidiary contact detailsPage Copyright 2006. Black Box Corporation. All rights reserved