Cisco Systems OL-12812-01 manual Voice Network Module LEDs, View from front of board

Page 7

Connecting Cisco Voice Network Modules to the Network

Voice Network Module LEDs

Step 3 Beginning with bank 0, insert the PVDM into the connector slot at an angle, tilted toward the right side of the chassis. Align the PVDM in a vertical position (see Figure 10) by using the minimum amount of force required. When the PVDM is properly seated, the socket guide posts fit through the alignment holes, and the connector springs click into place.

Step 4 Ensure that each PVDM is straight and that the alignment holes (as shown in Figure 9) line up with the plastic guides on the socket.

Figure 10

Installing PVDMs

View from front of board

1. Insert the PVDM into the socket at an angle from vertical.

2. Push the top of the PVDM down and back.

3. The socket guide posts fit through the holes in the PVDM.

4. The locking springs clip the back of the PVDM.

23604

Caution It is normal to feel some resistance, but do not use excessive force on the PVDM and do not touch the surface components.

Step 5 Repeat Step 2 through Step 4 for each PVDM.

Voice Network Module LEDs

All network modules have an enable (EN) LED. This LED indicates that the module has passed its self-tests and is available to the router. The following network modules have no additional LEDs. (See Figure 11 for a sample faceplate.)

NM-1V

NM-2V

NM-HD-1V

NM-HD-2V

NM-HD-2VE

Connecting Cisco Voice Network Modules to the Network

7

Image 7
Contents Voice Network Modules Connecting Cisco Voice Network Modules to the Network48-Channel High-Density Voice Network Modules 4-Channel Voice Network ModulesChannel High-Density Voice Network Module Packet Voice DSP Modules Pvdm Orientation Pvdm OrientationRemoving PVDMs Installing PVDMsView from front of board Voice Network Module LEDsVoice Network Module LED HDV Network Module LEDsNM-HDV2 Packet Fax or Voice DSP ModulesVIC-2DID Configuring E1 Ports for Normal or Wetting Current Mode NM-HDV2-2T1/E1 Jumpers Configured for Normal Mode Installing PVDM2 ModulesPVDM2 Module Slot Locations PVDM2 Module OrientationRemoving PVDM2 Modules Installing PVDM2 ModulesNM-HDV2 Network Module LEDs Installing PVDM2 ModulesNM-HDV2 Network Module LEDs Related DocumentsConnecting Cisco Voice Network Modules to the Network