Page 23 | Digital Display Wall Clock Guide | DDC2 / |
|
|
|
3-Wire Synchronous (24VAC Correction)
| H |
| M |
115VAC | GRND |
Local | AC IN |
Power | AC RTN |
24VAC | Return |
| |
From |
|
Master Clock | Correction |
BLK
BLK
BRN / WHT
BLU / WHT
To
Other Clocks
Clock will correct minutes hourly at HH:59 and hour and minutes twice daily at 5:59.
Wiring applies to secondary wall clocks such as:
Lathem type SS Cincinnati D10 IBM 77 Series
Simplex 77 Series,
Stromberg 3000
Set switches
Indicates depressed side of switch
1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 |
OPEN