2000 – 4000 Series Time Recorder User’s Guide
Changing the Motor
Figure 10
1.Unplug cord from wall outlet (except 2100BATT).
2.Remove type section from main frame (see “Replacing the Type Section”).
3.Figure 10 shows a close-up of cam block terminal.
4.Disconnect Motor Wire Leads – Figure 10, 10.1 by turning each Screw – 10.2
5.Remove the Motor Clutch – Figure 10, 10.3 from its shaft. The shaft has LEFT HAND threads – remove clutch by turning clockwise.
6.Hold Motor Bracket – Figure 10, 10.4 and loosen Motor Mounting Screws – Figure 10, 10.5. Remove and retain screws and bracket from old motor.
7.Install motor clutch on new motor. Turn counterclockwise to tighten. DO NOT OVERTIGHTEN OR BEND – YOU MAY DAMAGE INTERNAL MOTOR GEARS.
8.Install new motor.
9.Install the new motor wire leads into the cam block terminal – Figure 10, 10.1 by turning each Screw – 10.2
10.Plug cord back in wall outlet, and reset the time.