JVC BC-D2300U manual CONTROLS, Indicators and Connectors, Front panel

Page 3

CONTENTS

 

Major features

4

Notes on settings and use

4

HANDLING PRECAUTIONS

CONTROLS, INDICATORS AND CONNECTORS

Handling precautions

4

Installation in a rack

4

Controls, indicators and connectors

 

Front panel

5

Rear panel

6

Menu settings

 

Setting the menu

7

Sub menu

7

Storing menu settings in memory of this unit

8

Recalling stored menu settings or factory default

 

settings

8

Entering characters

9

Menu contents

10

Others

 

Error output

16

Rear panel connectors

18

Avoid using this unit in places subject to the following conditions:

direct sunlight

high humidity and dust

vibrations

extreme heat

These conditions can cause problems and may damage the unit.

Influence of strong electric waves and magnetism

Noise may appear on the screen when used in places close to a

transmission antenna, or in places near transformers and motors

where strong magnetism can occur.

This equipment is meant for use exclusively in commercial and

industrial applications. If used at home, it may cause

interference with radio and television reception.

To save electricity, shut off the power when the unit is not in use.

Use the supplied power cable for this unit.

Do not place heavy objects such as a television monitor on top of

the unit. Doing so could cause damage or adversely affect

Front panel

1

2

3

4

5

POWER

STATUS

INPUT

SYNC

 

 

 

 

 

 

 

 

LOCAL REMOTE

7

8

9

BC-D2300U HDTV UP CONVERTER

ENTER ESC

MENU

Installing the power cable hook

18

Specifications

19

Supplement

21

Optional software

For optional software, consult your JVC dealer. Using it without formal procedures is illegal.

MAJOR FEATURES

This unit converts SMPTE259M-standard SD digital serial signal input to the SMPTE292M-standard (1080I or 720P) HD digital serial signal for output.

Conversion modes are provided for input NTSC video signals with an aspect ratio of 4:3 (standard), in the letter box format or squeezed.

The delay time for video conversion is added to the embedded audio to synchronize audio and video for output.

Input signal can be cropped (in the 4:3 mode, independently for the left and right sides)

Background color can be set with hue, saturation and lightness.

It is possible to set or show the model name (up to 10 characters).

Each function can be set on the front panel with the LCD. The unit can also be remote-controlled via the 9-pin connector on the rear panel (RS-485 or RS-232C).

Menu settings can be saved in memory and loaded from memory.

Four independent memories are provided to store menu settings. Stored menu settings can be recalled as required.

Compact design allows this unit to be installed in a 1U EIA rack.

Color bar output possible.

External reference sync signal input connector

Three video/audio output connectors

Enhancer (contour correction), motion sensitivity, background color, screen horizontal/vertical position and system phase can be adjusted.

Error indication and alarm signal output function

Color correction function (option)

Variable enhancer (option)

NOTES ON SETTINGS AND USE

performance.

Do not put any foreign objects into the unit.

Do not disassemble the unit or try to modify it.

Do not block the ventilation openings.

Change the cooling fan about three years after installation of the

unit.

When cleaning the cabinet, wipe it with soft cloth. Do not use

benzene or thinner as these may deform or discolor the cabinet

surface. To remove excessive dirt, clean the unit with a mild

detergent diluted with water, then wipe it with dry cloth.

Do not use the unit in an environment exposed to gases

generated by chemicals or organic solvents.

INSTALLATION IN A RACK

This unit can be installed in EIA standard rack. Ensure sufficient rack strength by attaching L-metal supports on both sides of the rack on which you will place the unit.

1.Detach the four feet on the base of the unit.

2.Install the supplied rack mount brackets on both sides of front panel using the four supplied screws (M4).

3.Set this unit on the rack, and fix the rack mount brackets onto the rack using the four supplied screws (M5).

2.Rack mount bracket

 

2. Rack mount

 

bracket

1. Foot

2. Supplied

 

screw (M4) x 4

 

EIA rack

3. Supplied

 

screw (M5) x 4

 

10

1[POWER] indicator

Lights green when power is supplied to this unit.

2[STATUS] indicator

Normally lights green. Lights orange in the menu setting mode, when the set value is changed or the set data is transmitted to this unit. When the transmission is complete, this indicator lights green again. When errors occur in hardware, etc., this indicator lights red.

3[INPUT] indicator

Normally lights green. When no signal is input, this indicator lights orange. If there is an error in the input signals, this indicator lights red.

4[SYNC] indicator

Normally lights green. If a sync system-related error occurs, this indicator lights red.

For details on error indicators, see page 17.

5Display

When power is applied, the input/output or screen display mode is shown. (Normal display mode)

Model name:

The model name can be set with the menu (up to 10 characters). In the remote mode, the remote ID number (1 – 31) is shown following the model name.

(e.g.) BC-D2300 ID: 

B C – D 2 3 0 0

[ D 1 1 0 8 0 4 : 3 ]

Input form Output form Screen conversion mode

Memoranda:

The screen conversion mode can be selected with menu <Output Mode>.  p. 10.

Output form can be selected with menu <Output>.  p. 10.

When menu <Color Correction> is set to “ON” or <Colorimetry> is set to “OFF”, the normal display changes as follows.

6

6[+/–] button

Press this button to change the set value for a menu item in the menu setting mode.

7[/] button

Press this button to select the menu item in the menu setting mode.

8[ENTER/MENU] button

In the normal display mode, press this button to engage the menu setting mode.

In the menu setting mode, press this button to enter the set value for the following menu items. (? is shown.)

Output Mode item Output item Profile Save item Profile Load item

Use to enter the sub menu. ([ENTER] is shown.)

9[ESC] button

In the menu setting mode, press this button to restore the normal display mode.

Memorandum:

To use the menu setting, refer to pages 7 to 9.

0[LOCAL/REMOTE] switch

Use to select LOCAL or REMOTE to operate this unit. LOCAL : Set to this position to operate this unit with

the operation buttons on this unit.

REMOTE : Set to this position to remote-control this unit via the [REMOTE IN] connector or [ALARM] connector on the rear panel. Also, set to this position to lock the front panel’s operation buttons.

The factory preset is LOCAL.

When the menu item <Reference> is set to [INPUT] and there is no SD input signal, output video signals may be distorted. In this

case, input external sync signals and set <Reference> to [BB] or [HD-SYNC]. ( p. 10).

When the menu item <Reference> is set to [BB] or [HD-SYNC] and these external sync signals are not input or are incorrect, output video signals may be distorted. In this case, system phase cannot be assured. ( p.10)

See ‘‘Supplement’’ on page 21.

B C – D 2 3 0 0

[ D 1 / 1 0 8 0 / 4 : 3 ]

Change

Press the 8 [ENTER/MENU] button to display the item in the menu setting mode.

If an error occurs in the normal display mode, a description of the error is shown.  p. 17.

4

5

Image 3
Contents Victor Company of JAPAN, Limited For Customer UseSafety Precautions Front panel CONTROLS, Indicators and ConnectorsSub menu Menu SettingsSetting the menu Rear panelRecalling stored menu settings or factory default settings Menu contents contd Menu contentsChanged, check the color on the screen again HSLYCbCr Sets the output value of the background color Values1FRAME-90H Memory DefaultAlarm 1FRAMEError output contd Error outputOthers WHD Rear panel connectorsSpecifications Installing the power cable hookTo secure strength Specifications contdSupplement Put L-metal supports on the both sides of EIA rackMemo