Panamax 7500-PRO owner manual Technical Specifications

Page 10

TECHNICAL SPECIFICATIONS

GENERAL

 

 

 

 

Dimensions

17” W x 12.75” D x 3.5” H, (4.1” H including feet)

Weight

36 lbs.

 

 

AC CIRCUIT PROTECTION AND FILTRATION

 

AC POWER:

 

 

Line Voltage

120V, 60Hz

Regulation Range

100V-135V

Regulated Output

120V ± 2V

Total Current Capacity

15 A

Surge Suppression Rating

330V

Protection Modes

L - N, L - G, N - G

Initial Clamping Level

200V

Energy Dissipation

2670 Joules

Peak Impulse Current

162,000Amps

Catastrophic Surge

Circuit

Yes

Thermal Fusing

Yes

Over-voltage shutoff

142 VAC ± 5VAC

Under-voltage shutoff

90VAC ± 2 VAC

Ground Fault Circuit Interrupter (GFCI)

Banks 3 & 4

EMI/RFI NOISE FILTRATION:

 

Banks 1-4

100 dB, 100 KHz ± 2 MHz

Bank 5

60 dB, 100 KHz ± 2 MHz

 

 

 

USB LIGHT

 

 

Voltage

5VDC

Current

100mA

 

 

DC TRIGGER INPUT

 

Jacks

3.5 mm mono mini-plug

Voltage and Polarity

3-24V DC bidirectional

Current Requirement

4.6 mA @3V, 58mA @24V

 

 

 

DC TRIGGER OUTPUT

Voltage

<12V

Current

<400 mA

Short-circuit protection

Yes

Delay on output

10 seconds

LAN CIRCUIT

Clamping Level

8V ± 2V

Jacks

RJ-45

Wires Protected

4-Wires, pins 1, 2, 3 & 6

 

 

TELEPHONE CIRCUIT

Fuseless/Auto-Resetting

...................................................................................Yes

Clamping Level

260V

Capacitance

30pf (approx.)

Suppression Modes

Metallic & Longitudinal

Connections

RJ-11

Protected

2-Wires, Pins 4 & 5

 

 

SATELLITE TV CIRCUIT

Bidirectional

Yes

Shielded

Yes

Clamping Level

25V

Attenuation

<1 dB from 950MHz - 2.05GHz

 

<2.4db @ 2.2GHz

Connections

Female F, Gold Plated

 

 

CABLE TV CIRCUIT

Bidirectional

Yes

Shielded

Yes

Clamping Level

1.4V

Attenuation

<1 dB up to 950MHz

Shielded

YES

Connections

Female F, Gold Plated

 

 

Design and specifications subject to change without notice due to product improvement.

8

 

USA & Canada (800) 472-5555 • (707) 283-5900 • Fax (707) 283-5901

Image 10 Contents
MAX 7500-PRO Table of Contents Before YOU BeginImportant Safety Instructions Introduction Digital Source Components or Display DevicesConnection Diagram Step Feature Overview Power SwitchFeature Details Convenience Lamp Banks 1 and 2 Regulated OutletsCircuit Breakers DC TriggersTo protect a telephone jack Satellite TVTelephone Protection Please NoteTechnical Specifications Switch bank stateCR Command String Action ResponseTrigout Offdelay = 0-240 seconds For more information Setdelay bank ondelay offdelayCROndelay = 0-240 seconds $INVALIDPARAMETERCRResetallcr $FACTORY Settings RestoredcrQuery Description Response Query ?LISTCONFIGCRMessage Condition Message Troubleshooting$PWR = Recoverycr $PWR = UndervoltagecrProduct Upgrade Program