MAX PRO-SERIES Communication/Configuration Specifications (continued)

Command String

Action

Response

1.6

!SET_BRIGHT x<CR>

Sets the voltmeter, ammeter and LED

If x is valid, $BRIGHTNESS = x<CR>

 

x = {10 -100}

brightness to x%

If x is invalid, $INVALID_PARAMETER<CR>

 

Example: !SETBRIGHT 75<CR>

 

 

 

(sets meter brightness to 75%)

 

 

1.7

!SET_TRIGGER bank triggersource<CR>

Assigns the trigger(s) for an outlet bank

If bank and triggersource are valid,

 

bank = { 1, 2, 3, 4,HC1, HC2, TRIGOUT}

or DC trigger output. These trigger set-

$TRIGGER FOR bank = triggersource<CR>

 

tings are only used with the unit isset in

 

 

triggersource = { NONE, BUTTON, TRIGIN}

CUSTOM SETTING mode. See Page 4 for

If bank or triggersource are invalid,

 

more information.

$INVALID_PARAMETER<CR>

 

where

 

 

 

NONE = Outlet bank is always ON,

 

 

 

trigger output is OFF (RS232 only)

 

 

 

BUTTON = Trigger on front panel button.

 

 

 

TRIGIN = Trigger on DC input trigger

 

 

 

Example: !SET_TRIGGER 3 TRIGIN<CR>

 

 

 

(sets bank 3 to be controlled by the DC

 

 

 

trigger input only)

 

 

1.8

!SET_DELAY bank ondelay offdelay<CR>

Assigns the turn on and turn off delays for

If bank, ondelay and offdelay are valid,

 

bank = { 1, 2, 3, 4,HC1, HC2, TRIGOUT}

 

an outlet bank or DC trigger output. These

$DELAY FOR bank = ondelay offdelay<CR>

 

ondelay = { 0-240 } (seconds)

delay settings are only used with the unit is

 

 

set in CUSTOM SETTINGS mode. See Page

If bank, ondelay or offdelay are invalid,

 

offdelay = { 0-240 } (seconds)

4 for more information

$INVALID_PARAMETER<CR>

 

 

 

 

Example: !SET_DELAY 4 5 1<CR>

 

 

 

(sets bank 4 turn-on delay to 5 sec. and

 

 

 

turn-off delay to 1 sec.)

 

 

10

 

USA & Canada (800) 472-5555 • (707) 283-5900 • Fax (707) 283-5901

Image 12 Contents
MAX 7500-PRO Table of Contents Before YOU BeginImportant Safety Instructions Introduction Digital Source Components or Display DevicesConnection Diagram StepFeature Overview Power SwitchFeature Details Banks 1 and 2 Regulated Outlets Circuit Breakers Convenience Lamp DC TriggersSatellite TV Telephone ProtectionTo protect a telephone jack Please NoteTechnical Specifications Command String Action Response Switch bank stateCRTrigout Setdelay bank ondelay offdelayCR Ondelay = 0-240 secondsOffdelay = 0-240 seconds For more information $INVALIDPARAMETERCRResetallcr $FACTORY Settings RestoredcrQuery Description Response ?LISTCONFIGCR QueryMessage Troubleshooting $PWR = RecoverycrCondition Message $PWR = UndervoltagecrProduct Upgrade Program