Panamax 7500-PRO owner manual Feature Overview, Power Switch

Page 6

FEATURE OVERVIEW

1.Power Switch

Pushbutton; activates a turn-on or turn-off sequence for all outlets when depressed for two seconds.

2.Bank Status Indicators:

When on, indicates that the corresponding bank is on.

When off, indicates the corre- sponding bank is off.

When flashing, indicates the bank is in transition, either turning on or turning off.

3.Ground Isolation:

Controls the ground connec- tion of banks 3 and 4.

When active these banks have Balanced Power with an isolated ground connection.

When not active these banks have Balance Power with a common ground reference.

5. Voltmeter:

Backlit analog meter displays the incoming voltage between 90-140 VAC.

Integrated “Unsafe Voltage” indicator will flash after sensing an unsafe voltage and disconnecting all outlets.

Integrated “Out of Regulation” indicator will flash whenever the regulated output voltage is out of spec.

6. Combination Meter:

7. Ambient

Displays the regulated output voltage,

Light Sensor

90-140 VAC in one mode. Displays

 

the Input Current draw, 1-15 Amps,

 

in the alternate mode.

 

M7500-PRO

BANK 1 ON BANK 2 ON BANK 3 ON BANK 4 ON

POWER FILTRATION AND REGULATION ACTIVE

 

 

 

BRIGHTNESS

BANK 5

BANK 5

 

 

 

 

 

AUTO

HC 1 ON

HC 2 ON

 

 

HIGH CURRENT

GROUND

PRESS:

 

 

ISOLATION

METER SELECT

ACTIVE

HomeTheater Power Management

4. Brightness Control/Meter Select:

When in the full/locked left position, auto brightness is engaged, and the front panel display will dim with the ambient light level. Rotating the knob to the right will increase the display brightness, and left will decrease the display brightness.

Pressing this control will toggle the display of the second meter from “Volts Out” to “Amps In”.

8:Convenience Outlet:

Provides a quick convenient way to plug in components such as cam- corders and video game systems.

1. 15A Main Circuit

2. Filtered Regulated

3. Isolated (Switched)

4. High Current Outlet

5. Isolated Outlets

6. Satellite Coax Jacks:

8. Settings Option: Two-

Breaker: Opens in the

Outlets (BANKS 1 & 2):

Outlets (BANKS 3 & 4):

Bank (BANK 5): Two

Circuit Breaker:

Two pairs of F-Connectors

position slide switch. Switch

event that equipment

Four, Balanced Double L fil-

Four outlets provide complete

delayed outlets designed

Opens in the event that

optimized for Satellite TV

settings selects the use of the

plugged into the MAX

tered outlets for low current

isolation for digital source

for high current compo-

equipment connected to

signal line protection.

five switches to configure the

7500 draws too much

analog audio components

components such as DVD

nents such as amplifiers

the Isolation Transformer

Bi-directional

outlets for delayed or always-

current. When white is

such as pre-amplifiers,

players or display devices like

and powered subwoofers.

Outlets exceeds 6 Amps

 

on operation. Custom settings

visible, the breaker has

receivers, VCR's and tape

plasma TVs or DLP

The current available to

current draw. When white

7. CATV Coax Jacks:

selects the stored configuration

opened. Reduce the

decks.

projectors. These outlets are

connected equipment is

is visible, the breaker has

One pair of F-Connectors

in non-volatile memory for the

load and push to reset.

 

 

 

completely isolated from the

not limited by the noise

opened. Reduce the load

optimized for Cable TV,

outlets trigger source and

 

 

 

 

rest of the system.

filtration components.

and push to reset.

Antenna or Cable Modem

delays. See Page 10-15 for

 

 

 

 

 

 

 

 

signal line protection.

details.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Bi-directional

 

 

 

 

 

 

 

 

 

 

15 AMP CIRCUIT BREAKER

BANK 1 ALWAYS ON

BANK 2 SWITCHED

BANK 3 SWITCHED

 

BANK 4 SWITCHED

 

BANK 5 HIGH CURRENT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

REGULATED & ISOLATED FOR HD VIDEO

 

 

 

 

 

 

 

 

 

HD

 

 

 

 

 

HD

 

 

 

 

 

 

 

 

 

MONTHLY

 

SEEINSTRUCTIOS

 

 

 

 

 

SATELLITE

 

 

 

 

CATV / ANT

 

 

 

 

 

 

 

MONTHLY

 

 

 

 

 

 

SATELLITE 1

 

SATELLITE 2

 

CABLE 1

 

 

CABLE 2

 

 

 

 

 

 

 

 

 

 

CIRCUIT BREAKER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BANKS 3 AND 4

 

 

 

 

 

 

 

 

 

 

 

 

 

GROUND

 

 

 

 

TEST

RESET

TEST

RESET

 

 

HC 1

 

 

 

 

 

 

 

 

 

 

 

 

 

LUG

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DVR &

 

 

 

 

 

 

SWITCHED

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HD CABLE

 

 

 

 

 

 

SUB

 

 

 

 

 

 

 

 

 

 

 

 

 

SWITCH

 

 

REGULATED

DIGITAL

 

 

 

 

 

RECEIVER

 

ALWAYS

ALWAYS

 

ALWAYS

 

ALWAYS

ALWAYS

 

 

HD SAT

 

 

 

 

AMP

 

 

 

SETTINGS

 

MAIN POWER 120VAC/15A

 

 

RADIO

TEST

RESET

TEST

RESET

HC 2

 

ON

DELAY

ON

DELAY

ON

DELAY

ON

DELAY

ON

DELAY

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SEEINSTRUCTIOS

 

 

 

 

SWITCHED

 

 

 

 

 

 

 

 

 

 

 

 

COMMUNICATIONINTERFACE

 

 

 

 

 

 

 

 

 

 

TRIGGER

BANK 2

BANK 3

BANK 4

5 HC 1

 

5 HC 2

CUSTOM

 

 

 

 

 

 

TEST

 

 

 

 

 

 

 

 

LAN

 

PHONE

 

PHONE LINE

PHONE LINE

 

 

 

 

 

TEST

 

 

 

INPUT

OUTPUT

 

LAN

 

 

 

SETTINGS

 

 

 

 

 

 

 

 

 

LINE IN

 

TO EQUIP

 

LINE IN

 

TO EQUIP 1

 

TO EQUIP 2

 

 

 

 

 

 

 

 

 

3-24VDC

12V/400mA

 

 

 

 

 

 

 

 

 

 

USB LIGHT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5VDC/100mA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12 AMP MAX

 

 

6 AMP MAX

 

 

6 AMP MAX

 

 

15 AMP MAX

 

 

 

 

 

 

 

 

 

 

 

 

 

9.IEC Main Power Receptacle:

Detachable power cord connects to this recep- tacle.

10.Ground Lug: Provides a common grounding point for equipment with separate ground leads

11.DC Trigger Input:

3.5mm (1/8”) Mini-Plug jack. Connect to a remote trigger device that uses a DC voltage signal to initiate a startup/shut- down sequence.

12.DC Trigger Output: 3.5mm (1/8”) Mini-Plug jack. The M7500-Pro generates its own 12VDC trigger to control another device.

14. LAN:

In/Out connections for Ethernet.

13.Outlet Delay Switches:

Two-position slide switches. Allows for the user to configure each bank for delayed turn-on/turn-off or always-on operation.

15.Telephone Jacks:

1In & 2 Out connections for telephone line or pay-per-view line protection.

16.Lamp Receptacle: USB jack. The convenience lamp included with the M7500- Pro is to illuminate the rear panels of other com- ponents during setup.

17.Communications Interface: RS232 interface for custom con- figuration and/or home automation control. Contact Panamax for availability of alternate TCP/IP interface.

4

 

1690 Corporate Circle, Petaluma CA 94954 • www.panamax.com

Image 6 Contents
MAX 7500-PRO Table of Contents Before YOU BeginImportant Safety Instructions Introduction Digital Source Components or Display DevicesConnection Diagram StepFeature Overview Power SwitchFeature Details Convenience Lamp Banks 1 and 2 Regulated OutletsCircuit Breakers DC TriggersTo protect a telephone jack Satellite TVTelephone Protection Please NoteTechnical Specifications Command String Action Response Switch bank stateCRTrigout Offdelay = 0-240 seconds For more information Setdelay bank ondelay offdelayCROndelay = 0-240 seconds $INVALIDPARAMETERCRResetallcr $FACTORY Settings RestoredcrQuery Description Response ?LISTCONFIGCR QueryMessage Condition Message Troubleshooting$PWR = Recoverycr $PWR = UndervoltagecrProduct Upgrade Program