Honeywell VR8304 Instructions to the Homeowner, Service, Turning off the Appliance

Page 8

VR8304 INTERMITTENT PILOT COMBINATION GAS CONTROL

Service

WARNING

Fire or explosion hazard. Can cause property damage, severe injury, or death.

Do not disassemble the gas control; it contains no replaceable components. Attempted disassembly or repair may damage the gas control.

CAUTION

Do not apply a jumper across or short the valve coil terminals. Doing so may burn out the heat anticipator in the thermostat or damage the electronic module.

IMPORTANT

Allow 60 seconds after shutdown before re- energizing the step-opening module to ensure lightoff at steppressure.

IF MAIN BURNER WILL NOT COME ON WITH CALL FOR HEAT

1.Ensure the gas control knob is in the ON position.

2.Adjust the thermostat several degrees above room temperature.

3.Using an AC voltmeter, check for 24V at gas control.

If pilot lights, measure across MV/PV and MV.

If pilot does not light, measure across MV/PV and PV before safety lockout occurs.

4.If voltage is incorrect or not present, check control circuit for proper operation.

5.If 24V is present, replace the gas control.

INSTRUCTIONS TO THE HOMEOWNER

WARNING

Fire or explosion hazard. Can cause property damage, severe injury, or death.

Follow these warnings exactly:

1.Pilot flame is lit automatically. Do not light the pilot flame manually.

2.Before lighting the pilot burner flame, smell around the appliance for gas. Be sure to smell close to the floor because LP gas is heavier than air.

3.IF YOU SMELL GAS:

Turn off the gas supply at the appliance service valve on LP gas systems, turn off gas supply at the gas tank.

Do not light any appliances in the house.

Automation and Control Solutions

Do not touch electrical switches or use the phone.

Leave the building and use a neighbor’s phone to call your gas supplier.

If you cannot reach your gas supplier, call the fire department.

4.Do not force the gas control knob. Use only your hand to push down or turn the gas control knob. Never use tools. If the gas control knob will not operate by hand, the gas control should be replaced by a qualified service technician. Force or attempted repair may result in a fire or explosion.

5.The gas control must be replaced in case of any physical damage, tampering, bent terminals, miss- ing or broken parts, stripped threads, or evidence of exposure to heat.

IMPORTANT

Follow the operating instructions provided by the manufacturer of your heating appliance. The information below will be of assistance in a typi- cal gas control application, but the specific con- trols used and the procedures outlined by the manufacturers of your appliance may differ, requiring special instructions.

STOP! READ THE WARNINGS ABOVE!

The pilot flame is lit automatically. If the appliance does not turn on when the thermostat is set several degrees above the room temperature, follow these instructions.

1.Set the thermostat to its lowest setting to reset the safety control.

2.Disconnect all electric power to the appliance.

3.Remove the gas control access panel.

4.Push in the gas control knob slightly and turn

clockwise to OFF.

5.Wait five minutes to clear out any unburned gas. If you then smell gas, STOP! Follow Step 3 in the Warnings above. If you do not smell gas, continue with the next step.

6.Turn the gas control knob counterclockwise to

PILOT.

7.Turn the gas control knob counterclockwise to ON.

8.Replace the gas control access panel.

9.Reconnect all electric power to the appliance.

10.Set the thermostat to the desired setting.

11.If the appliance does not turn on, set the gas con- trol knob to OFF and contact a qualified service technician for assistance.

Turning off the Appliance

VACATION SHUTDOWN—Set the thermostat to the desired room temperature while you are away.

COMPLETE SHUTDOWN—Push the gas control

knob in slightly and turn clockwise to OFF. Do not force. Appliance will completely shut off. Follow the lighting procedures above to resume normal operation.

Honeywell International Inc.

Honeywell Limited-Honeywell Limitée

1985 Douglas Drive North

35 Dynamic Drive

Golden Valley, MN 55422

Toronto, Ontario M1V 4Z9

customer.honeywell.com

 

® U.S. Registered Trademark

 

© 2008 Honeywell International Inc.

Printed in Mexico

69-0625—03 K.K. Rev. 10-08

 

Image 8
Contents Specifications ApplicationInstallation Install Adapters to Gas ControlUsing Adapters to Solve Swing Radius Problems Converting Between Natural and LP GasInstall Piping to the Gas Control Install the Gas ControlChoose Gas Control Location Connect Pilot Gas TubingWiring Gas Control Knob SettingsStartup and Checkout Turn on the SystemLimit Perform Gas Leak Test Adjust the Pilot Burner FlameCheck and Adjust Gas Input to Main Burner Maintenance Check Safety and Shutdown PerformanceService Automation and Control SolutionsInstructions to the Homeowner Turning off the Appliance

VR8304 specifications

The Honeywell VR8304 is a sophisticated and reliable gas valve designed for use in residential and commercial heating applications. This integrated system is primarily used in conjunction with gas-fired appliances such as furnaces, boilers, and water heaters, offering improved efficiency and performance.

One of the standout features of the VR8304 is its dual combination of safety and comfort, thanks to its electronic ignition and safety shutoff mechanisms. This gas valve is equipped with a built-in pilot safety system that ensures safe operation. In the event of a failure in the ignition system, the VR8304 automatically shuts off the gas flow, preventing any potential hazards.

The unit is designed for compatibility with natural gas or propane, making it versatile for various heating needs. It utilizes a robust solenoid-operated design, which enhances its responsiveness. The VR8304 also boasts a high heat capacity, allowing it to efficiently handle significant gas flow for both heating and domestic hot water applications.

One of the technological advancements found in the VR8304 is its adaptive control features. The valve can adjust the gas flow rate depending on the demand, which not only optimizes fuel efficiency but also enhances the comfort of the environment by maintaining consistent temperature levels.

Installation of the VR8304 is straightforward due to its compact size and intuitive design. It fits standard piping configuration, reducing the need for complex adjustments or modifications during installation. Furthermore, its durable construction ensures long-lasting performance, with resistance to common issues such as corrosion and wear.

Another important characteristic of the Honeywell VR8304 is its low operating pressure combined with extended operating range. This ensures effective operation across various environmental conditions and helps maintain system integrity over time.

Finally, the Honeywell VR8304 is backed by robust customer support and service options, ensuring users have access to assistance and information to maximize their system's efficiency and safety. In conclusion, the Honeywell VR8304 stands out as a highly efficient, durable, and versatile gas valve for any heating application. Its innovative features and technologies provide both safety and performance, making it a top choice among HVAC professionals and homeowners alike.