Hitachi CMP4212, CMP4211 Other Features Signal Check, Power Save Mode, Status Display Action

Page 25

OTHER FEATURES (continued)

Signal Check

Changes in the signal status are displayed on the screen as they arise.

Status

Display

 

Action

 

 

 

 

 

When Mode Display is set to ON,

A guide is displayed for the input

 

 

 

the input signal is switched or

terminal and the horizontal and

 

 

 

when the RECALL button is

vertical sync frequency.

 

 

 

pressed.

 

 

 

 

 

 

 

 

 

When the sync signal is no longer

• A guide displays No Sync.

Recheck the personal computer

detected.

Signal, and Power Save (for

power switch status and the

 

approx. 5 sec.)

connection status.

 

• When the condition continues

 

 

 

 

where the sync signal cannot be

 

 

 

 

detected, indicator lamp of

 

 

 

 

power source changes in

 

 

 

 

orange and the mode switches

 

 

 

 

to power save mode.

 

 

 

 

 

 

 

 

When the input signal does not

A guide displays Invalid Scan

Recheck the input signal

match the monitor specifications

Freq.

specifications.

or is in an unstable status.

 

 

30 32

 

 

 

 

 

 

 

 

RGB

RGB2

RGB

H : 48.4kHz

V : 60.1 Hz

OFF -- -- Min.

-- -- : -- --

! No Sync. Signal

! Invalid Scan Freq.

ENGLISH

Power Save Mode

When the RGB1, RGB2 input is selected

When this unit is connected to a VESA DPMS computer, the Power Save (Off) mode can be set to be activated automatically when the computer is not being used to reduce power consumption by this unit.

RGB sync signal

Horizontal

Yes

No

 

Yes

 

No

 

 

 

 

 

 

 

Vertical

Yes

Yes

 

No

 

No

 

 

 

 

 

 

 

 

 

 

 

PC signal

Active (normal display)

 

Blank (no display)

 

 

 

 

 

 

 

 

 

Operation mode

On

 

 

Off

 

 

 

 

 

 

 

 

 

Indicating lamp

Lights green

 

 

Lights orange

 

 

 

 

 

 

 

 

 

 

 

3W or less (RGB1)

 

Power consumption

365W

1W or less (RGB2 ; 100VAC120V)

 

 

 

3W or less (RGB2 ; 120VAC240V)

 

 

 

 

 

 

 

 

Returning to operating status

Operate the personal computer, or press either the INPUT SELECT button of the main unit or the RGB1/RGB2 buttons of the remote control.

25

Image 25
Contents CMP4211 black CMP4212 silver Important Safety Instructions Prevention of Screen Burn Features Contents About the Symbols Safety InstructionsBe cautious of the power cord connection Safety InstructionsBe sure to keep safety ground connection Be careful in handling the battery of the remote controlRemove the power cord for complete separation Avoid a high temperature environmentInstallation environment How to view the monitorPrecaution during transportation Precautions for the cable connectionDo not physically impact the remote control Set the sound volume at a suitable levelFCC Federal Communications Commission Statement Warning CPU Boards and Power Supplies usedDeclaration of Conformity Class B Personal ComputersMain Unit Component NamesHandling the Remote Control Component Names Remote controlLoading Batteries Installation Installation InstructionsAnti-tumble measures Securing to a wall or pillarConnecting to a PC Installation InstructionsMonitor rear panel English Operating Instructions Turning Power On and OffIndicating lamp Input Switching Operating Instructions Volume AdjustmentWhen a button is pressed, the volume adjustment Audio MuteInput Signal Screen Display Size SwitchingDisplay area selection diagram RGB input Operating InstructionsAutomatic Adjustment of Screen Position and the Clock Operating Instructions Using the Menu ScreenOn-screen display system Independent Operation of Multiple Monitors ID NoPicture Menu Audio Menu Timer Menu60Min Function MenuSetup Menu Language Menu Other FeaturesAutomatic Store Menu Display Registration conditionPower Save Mode Other Features Signal CheckWhen the RGB1, RGB2 input is selected Status Display ActionMethods to Reduce the Occurrence of Image Retention Image Retention of Plasma DisplayAbout screen defects About residual imagesSymptoms That Seemingly Appear to be Failures TroubleshootingCheck the way the signal cable is connected Check to see if the input signal matches the monitorSymptom Point to check Example Troubleshooting Actions to Correct Abnormal DisplaysSignal Input Product SpecificationsRGB terminal D-sub 15-pin connector Pin Input signalRecommended Signal List Product Specifications Signal InputWith Digital RGB signal input RGB1 input DVI terminal DVI-DWith Analog RGB signal input RGB2 input Product Specifications Recommended Signal ListSupplement An example of connecting video imaging devices Connecting to a Video Imaging DeviceWith DVI-STB and RGB component setup Optional Video Unit FunctionAV1 AV2 AV3 RGB2 RGB1 AV4 Display size selection diagramFull Press Using a wide-screen monitorPictures Split Operating Instructions Displaying Multi PictureYNR Operating Instructions Picture Menu Item is added to the Menu shown Color System SystemVideo Input AV2 1st stepAudio Input Operating Instructions Setup MenuScart Output RGB2 1st step RGB2 2nd stepVideo input Scart connector pin specifications Input connector pin specificationsNot Used With component input AV1, AV2 and RGB2-component input With R, G, B Video input AV2 and AV4 inputKHz MHz

CMP4211, CMP4212 specifications

Hitachi CMP4212 and CMP4211 are renowned models within the realm of industrial-grade flat panel displays, known for their advanced technologies and features suited for various applications, including professional broadcasting, healthcare, engineering, and digital signage. These models showcase Hitachi's commitment to providing high-quality visual solutions while integrating innovative technologies designed to enhance user experience and reliability.

One of the defining characteristics of the CMP4212 and CMP4211 is their impressive display performance. Both models feature a 42-inch diagonal screen, delivering vibrant colors and incredible image clarity. Equipped with high-resolution capabilities, the displays provide sharp and detailed visuals, making them ideal for environments where precision and clarity are paramount. With a contrast ratio that ensures deep blacks and bright whites, users can expect enhanced visibility in various lighting conditions.

These models utilize advanced LCD technology, ensuring a wide viewing angle. This is particularly beneficial in settings where multiple viewers are positioned at different angles, allowing for consistent image quality across the viewing plane. Additionally, the displays incorporate Hitachi's proprietary image enhancement technologies, which further improve picture quality and reduce visual artifacts, ensuring that the images presented are both accurate and appealing.

Durability is another hallmark of the CMP4212 and CMP4211. Designed for heavy-duty usage, these displays are built to withstand the rigors of demanding environments. Their rugged construction, along with protective glass overlay, ensures that the screens are resilient against scratches and impacts. This makes them an excellent choice for hospitals, control rooms, and other locations where longevity is crucial.

In terms of connectivity, both models offer a variety of input options, including HDMI, VGA, and component video, enabling compatibility with a wide range of devices. This versatility simplifies integration into existing systems, allowing for seamless operation whether used for presentations, video playback, or complex data displays.

Energy efficiency is another noteworthy aspect of the CMP4212 and CMP4211. With advancements in power management, the displays consume significantly less energy compared to traditional models. This not only reduces operational costs but also supports environmentally friendly practices.

In summary, Hitachi CMP4212 and CMP4211 stand out due to their remarkable display performance, durability, versatile connectivity, and energy efficiency. These features make them ideal candidates for any professional environment where high-quality visual presentation is crucial, ensuring that they continue to meet the demands of users across various industries.