Crown 2400, 1200, 2401 Accessories Cooling Fan Options, Input Connectors Option, Filter Cleaning

Page 14

5 Advanced Features

and Options

5.2 Accessories

5.2.1 Cooling Fan Options

Every Micro-Tech amplifier has a built-in high- velocity fan that provides optimum cooling. Two optional replacement fan blades are avail- able for special cooling requirments. Crown part C 6594-3 is a quieter, low-velocity fan blade that in many cases can provide adequate cooling. Crown part C 6593-5 is a reverse air flow fan blade which changes the direction of the air flow in and out of the amplifier (not rec- ommended for the Micro-Tech 2400).

Important: The optional replacement fan blades should only be installed by a qualified technician.

5.2.2 Input Connectors Option

The MT-BB is an accessory panel that provides barrier-block input connectors. An MT-BB accessory might be desirable in applications requiring bare wire con- nections. It can also be used to daisy- chain an input signal from one amplifier to another, just like the MT-XLR

The MT-BB must be installed at an authorized service center or the Crown factory.

Micro-Tech Series Power Amplifiers

5.3 Filter Cleaning

A dust filter is provided on the air intake to the cooling system (Figure 4.1, letter “B”). If this filter becomes clogged, the unit will not cool as efficiently as it should and may produce lower- than-normal output levels due to high heat-sink temperature.

To remove the filter, use a phillips screwdriver to remove the three screws that hold the front

grille in place. Wash the filter with mild dish- washing detergent and warm water. Be sure to

dry the filter before installing it. ReplacementFigure 5.1 MT-BB Input Panel Accessory filters may be ordered from the factory.

Dust filters are not 100% efficient. So, depend- ing on the local environment, the internal heat sinks of the amplifier will benefit from periodic cleaning by a qualified technician. Internal cleaning information is available from our Technical Support Group.

page 14

Operation Manual

Image 14
Contents 03/03 Micro-Tech 600, 1200 601, 1201Some models may be exported under the name Amcron Watch for These Symbols Important Safety InstructionsOutput wiring Magnetic FieldTable of Contents Welcome How to Use This ManualFeatures Unpacking Your AmplifierYou may also stack amps without using a cabi- net SetupInstall Your Amplifier Unpack Your AmplifierChoose Input Wire Connectors Shows connector pin assignments forChoose Output Wire and Con- nectors Output ConnectionsInputs Connect input wiring to Channel 1 only Wire Your System Stereo ModeBridge-Mono Mode Parallel-Mono ModeSet Input Sensitivity Set Ground Lift SwitchStartup Procedure Connect to AC MainsDo Not operate the amplifier with the Odep LEDs turning off PrecautionsOperation Power Switch Odep Indicators Output Device Emulation Protection Enable Indicator Dust FilterReset Switches Micro-Tech 2400 only Rear Panel Facilities Power CordStereo/Mono Modes Switch Ground Lift SwitchAdvanced Features Options Filter Cleaning Accessories Cooling Fan OptionsInput Connectors Option Circuit Theory Principles of OperationOverview Stereo Operation Only ONE Channel ShownBridge-Mono Operation Parallel-Mono OperationTroubleshooting High-voltage power supply fuse or breaker has blown120 VAC, 60 Hz Units, Parallel mono mode Specifications120 VAC, 60 Hz Units, Bridge mono mode Weight 120VAC, 60-Hz units Net Weight Power Draw at IdleDimensions Width, Height, Depth Shippping WeightAC Power Draw Thermal Dissipation AC Power Draw Thermal Dissipation Service Warranty Items Excluded from this CROWN- Warranty Worldwide Except USA & CanadaThis page intentionally left blank Enclose this Portion with the UNIT. do not Mail Separately Crown Factory Service InformationNature of Problem