Crown 2400, 1200 775V sensitivity, 4V sensitivity, Required AC Mains, Power Draw at Idle, Cooling

Page 20

 

 

 

Micro-Tech Series Power Amplifiers

 

8 Specifications

 

 

 

 

 

 

 

 

 

Performance

MT-600

MT-1200

MT-2400

 

 

 

 

 

 

Voltage Gain (at maximum level setting, ± 0.5 dB)

 

 

 

 

26dB sensitivitiy

26 dB

26 dB

26 dB

 

0.775V sensitivity

35.0 dB

36.0 dB

38.0 dB

 

1.4V sensitivity

30.0 dB

31.0 dB

33.0 dB

 

 

 

 

 

 

Required AC Mains

50/60 Hz, 100 - 240 VAC (±10%)

50/60 Hz, 100 - 240 VAC (±10%)

50/60 Hz, 100 - 240 VAC (±10%)

 

 

 

 

 

 

Power Draw at Idle

90 watts

90 watts

90 watts

 

 

 

 

 

 

Cooling

Flow-through ventilation from front to side

Flow-through ventilation from front to side

Flow-through ventilation from front to side

 

 

 

panels. Internal heat sinks with forced air

panels. Internal heat sinks with forced air

panels. Internal heat sinks with forced air

 

 

 

cooling.

cooling.

cooling.

 

 

 

 

 

 

Dimensions: Width, Height, Depth

EIA Standard 19 in. x 3.5 in. (8.9cm)

EIA Standard 19 in. x 3.5 in. (8.9cm)

EIA Standard 19 in. x 3.5 in. (8.9cm)

 

 

 

x 16 in. (40.6 cm)

x 16 in. (40.6 cm)

x 16 in. (40.6 cm)

 

 

 

 

 

 

Weight (120VAC, 60-Hz units)

 

 

 

 

Net Weight

36 lb 4 oz (16.5 kg)

41 lb 1 oz (18.6 kg)

46 lb 14 oz (21.3 kg)

 

Shippping Weight

41 lb 2 oz (18.7 kg)

45 lb 3 oz (20.5 kg)

55 lb 12 oz (25.3 kg)

 

 

 

 

 

 

Weight (International units)

 

 

 

 

Net Weight

38 lb 7 oz (17.9 kg)

41 lb 0 oz (18.6 kg)

47 lb 9 oz (21.6 kg)

 

Shipping Weight

44 lb 2 oz (20.0 kg)

45 lb 4 oz (20.5 kg)

56 lb 6 oz (25.6 kg)

 

 

 

 

 

 

 

page 20

Operation Manual

Image 20
Contents 03/03 Micro-Tech 600, 1200 601, 1201Some models may be exported under the name Amcron Important Safety Instructions Output wiringWatch for These Symbols Magnetic FieldTable of Contents How to Use This Manual FeaturesWelcome Unpacking Your AmplifierSetup Install Your AmplifierYou may also stack amps without using a cabi- net Unpack Your AmplifierChoose Input Wire Connectors Shows connector pin assignments forChoose Output Wire and Con- nectors Output ConnectionsWire Your System Stereo Mode Bridge-Mono ModeInputs Connect input wiring to Channel 1 only Parallel-Mono ModeSet Ground Lift Switch Startup ProcedureSet Input Sensitivity Connect to AC MainsDo Not operate the amplifier with the Odep LEDs turning off PrecautionsOperation Odep Indicators Output Device Emulation Protection Enable IndicatorPower Switch Dust FilterRear Panel Facilities Power Cord Stereo/Mono Modes SwitchReset Switches Micro-Tech 2400 only Ground Lift SwitchAdvanced Features Options Filter Cleaning Accessories Cooling Fan OptionsInput Connectors Option Circuit Theory Principles of OperationOverview Stereo Operation Only ONE Channel Shown Bridge-Mono Operation Parallel-Mono OperationTroubleshooting High-voltage power supply fuse or breaker has blown120 VAC, 60 Hz Units, Parallel mono mode Specifications120 VAC, 60 Hz Units, Bridge mono mode Power Draw at Idle Dimensions Width, Height, DepthWeight 120VAC, 60-Hz units Net Weight Shippping WeightAC Power Draw Thermal Dissipation AC Power Draw Thermal Dissipation Service Warranty Items Excluded from this CROWN- Warranty Worldwide Except USA & CanadaThis page intentionally left blank Enclose this Portion with the UNIT. do not Mail Separately Crown Factory Service InformationNature of Problem