TLP 1000MV and TLP 1000TV • Setup Guide (Cont’d)
Wall-Mounting or Furniture-Mounting the TLP 1000MV
To mount the TLP 1000MV directly into a wall, follow these steps. The steps will be similar if the unit is mounted in furniture (such as a podium or table).
1.Use the template provided to mark the wall at a suitable location and cut a hole 10.06 inches (25.55 cm) wide x 6.98 inches (17.73 cm) high.
2.Unpack the TLP 1000MV and remove the faceplate.
3.Ensure all the locking arms are flush with the unit and that the TLP 1000MV can fit into the hole. If necessary, use a rasp or a coarse file to enlarge the hole.
4.Run the network and MTP cable connections inside the wall to the hole, leaving enough slack in the cables to connect them to the back of the TLP 1000MV.
5.Plug the cables into the rear panel connectors (see page 2).
Faceplate Snaps to Unit (4 plcs ea side)
Tighten Screws to
Rotate Locking Arms
zz
zz
zz
Connect the LAN port to the PoE power supply and network.
Connect the
Optional: Extron recommends using the Power over Ethernet power supply provided. However, you may use the LAN port only as a network connection and connect a 12 VDC, 1.0 A power supply (not provided) to the
6.Push excess cables into the wall cavity.
7.Ensure the five locking arms (three at the top and two at the bottom) are flush with top and bottom of the TLP 1000MV and fit the touchpanel into the hole.
8.Use a Phillips head screwdriver to tighten the screws for the locking arms. As the screws tighten, the locking arms rotate behind the wall and hold the unit in place. Do not overtighten the screws as this can damage the catches or the wall.
9.If required, perform the initial calibration (see page 3).
10.Replace the faceplate by pressing the catches on the faceplate into the corresponding holes on the front of the panel.
Reset Modes
The touchpanels have four reset modes: Factory Firmware Mode, Run or Stop Events Mode, Reset All IP Settings Mode, and Reset Factory Defaults Mode. These modes can be initiated by pressing the reset button (see “TLP 1000MV Reset Buttons and LED“ for the TLP 1000MV or “Rear Panel Features“ for the TLP 1000TV). For full information about these different modes, see the TLP 1000MV and TLP 1000TV User Guide.
Screen Design and Configuration
Use Extron GUI Configurator (version 1.2 or later) to design the graphical user interface that will appear on the TouchLink panel. Use Extron Global Configurator (version 3.1 or later) to assign functions to the elements of the graphical user interface. For complete information about these software programs, see the help file of the appropriate program.
Extron USA - West | Extron USA - East | Extron Europe | Extron Asia | Extron Japan | Extron China | Extron Middle East |
|
Headquarters |
|
|
|
|
|
|
|
+800.633.9876 | +800.633.9876 | +800.3987.6673 | +800.7339.8766 | +81.3.3511.7655 | +400.883.1568 | +971.4.2991800 |
|
+81.3.3511.7656 FAX | +971.4.2991880 FAX |
| |||||
Inside USA/Canada Only | Inside USA/Canada Only | Inside Europe Only | Inside Asia Only | Inside China Only |
| ||
|
|
| |||||
+1.714.491.1500 | +1.919.863.1794 | +31.33.453.4040 | +65.6383.4400 |
| +86.21.3760.1568 |
|
|
+1.714.491.1517 FAX | +1.919.863.1797 FAX | +31.33.453.4050 FAX | +65.6383.4664 FAX |
| +86.21.3760.1566 FAX |
|
|
|
|
|
|
|
|
|
|
| © 2011 Extron Electronics All rights reserved. | www.extron.com | |||||
| 03 11 |
4