Fostex VR800 owner manual Basic recording procedure, Mixer

Page 17

VR800 Quick Operation Guide

Basic recording procedure

The following explanation assumes that an external SCSI device is connected to the VR800 as the current drive, and a digital mixer is connected to the DATA IN/OUT connectors of the VR800. (Refer to “Connecting a SCSI drive” and “Connecting a digital mixer” for details.)

*Initialize the VR800.

*Set the sampling frequency of the digital mixer to 44.1kHz.

Current SCSI drive

3

2

4

ACCESS

OL 0

6

12

24

1 2 3 4 5 6 7 8A SYNC

RECORD TRACK

1

2

3

4

5

6

7

8

 

 

AUTO RTN

 

CLIPBOARD

 

 

 

AUTO PUNCH

 

 

 

EXIT

EXECUTE

START

IN

OUT

END

IN

OUT

/ NO

/ YES

 

 

 

PREVIEW

 

 

EJECT

 

HOLD/

STORE

EDIT

UNDO / REDO

DISP SEL

SETUP

 

 

PGM SEL

 

 

 

 

 

 

 

 

 

AUTO RTN

 

 

 

 

JOG

 

VARI PITCH

AUTO PLAY

LOCATE

TIME BASE SEL

SCRUB

 

SHUTTLE

SHIFT

P.EDIT

 

LOC MEM

 

 

 

 

RECORD

 

STOP

PLAY

REW

F FWD

 

 

AUTO

 

CLIPBOARD PLAY

 

 

 

 

PUNCH

 

LOCATE ABS

0

 

 

 

 

 

 

LOCATE REC END

 

 

 

 

1, 5

7

6

Digital Mixing Console

Music instruments

1. Turn on the power to the VR800, SCSI drive, and digital

mixer.

The VR800 should display the top of Program 1 (Time Base: ABS). [DIGITAL] lights up on the display. (After formatting, Program 1 is created, the digital input track is set to [adat], and the digital-in clock is set to “ASYnC (asynchronous).”

This indicator lights up when the VR800 receives adat digital signals from the mixer correctly.

DIGITAL44.1kHz

Adjusting the recording level

The VR800 does not have any recording level controls. You need to adjust the recording level on the device that outputs recording data. Use the group master faders on the mixer (faders that control the output level of ADAT OUT). Set the recording tracks on the VR800 to input monitoring status so that you can check the level adjustment.

2. Press the RECORD button once. (The RECORD button lamp

ABS

M

S

F

 

 

PGM

 

SYNC OUT

DRIVE

 

CLK

SCSI

 

AUTO

A.PUNCH

The digital-in clock is set to “ASYnC (asynchro- nous)” and this indicator lights up.

Selecting a recording track

1. Press the RECORD TRACK select key of the desired

recording track to set it in READY mode.

The RECORD TRACK select key lamps (red) for tracks in READY mode start to flash.

flashes.)

The “ready” tracks enter the input monitoring status.

As you raise the group output level on the mixer, the level meter segments of the ready tracks light up. Adjust the level so that the [0] to [3] level segments of the level meter light up at the highest peak.

If the [OL] segments of the meter light up, the recording level is too high. If the recording level is too high on a digital recorder, the recording signal may distort, unlike an analog recorder. Especially, if you are recording vocal or acoustic instruments, the recording level may suddenly peak.

In this case, you may want to lower the signal peak by applying a compressor/limiter using an insertion connector.

17

Image 17
Contents Quick Operation Guide ModelSafety Instructions Table of Contents Recording media Using an E-IDE hard diskInstall the included brackets on the hard disk Installing an E-IDE hard disk in the VR800Replacescrews. the bottom panel using the same six Place the VR800 on the flat level surface soConnecting a Scsi drive to the VR800 Using a Scsi driveScsi ID number setting Insert a disk in the Scsi drive Turn on the power to the connected Scsi drive and the VR800Formatting initializing a disk Use the JOG dial to select the desired record mode When SURE? appears, press the EXECUTE/YES keyIDE will light For details, refer to Press the EXIT/NO key to quit the setup modePress the Setup key to change to Setup mode Checking the record mode of the formatted diskChecking available recording time on a formatted disk Formatting the disk againPress and hold down the Shift key and press the EXIT/NO key Before turning off the power to the VR800Ejecting a removable disk from the Scsi drive Scsi drive is the current drive Connecting a digital mixer equipped with adat I/O Connecting a mixerAbout changing the digital-in clock setting Connecting an analog mixing consoleAbout sampling frequency Initial settingsBasic recording Press the Record button once. The Record button lamp Basic recording procedureMixer Undo and redo recording To cancel the undo operation, press the UNDO/REDO key againPress the Stop button to finish recording Press the Play buttonWhen you finish overdubbing, stop the VR800, locate Multitrack recording using overdubbingPing-pong recording Press the Record button onceRecording in a new program MixdownSelecting the desired program from multiple programs Basic Locate functionLocating the top of the program Locating the end of the recorded area of the programProcedures vari pitch function Playback using the Vari-pitch functionKey To turn off vari pitch mode, press the Vari Pitch keyReference pages Fostex Corporation