3. Setup

 

AC Power

Warning!

Verify that the power requirement label on your unit matches the line voltage

 

applied. All fixtures must be connected to circuits with a suitable Earth Ground.

 

To determine the power requirements for a particular fixture, see the label affixed to the back plate

 

of the fixture or refer to the fixture’s specifications chart.

 

A fixture’s listed current rating is its average current draw under normal conditions.

 

All fixtures must be powered directly off a switched circuit and cannot be run off a rheostat

 

(variable resistor) or dimmer circuit, even if the rheostat or dimmer channel is used solely for a 0%

 

to 100% switch.

 

Before applying power to a fixture, check that the source voltage matches the fixture’s

 

requirement.

 

All fixtures must be connected to circuits with a suitable Earth Ground.

Power Cable Configuration

CABLE

Pin

International

Screw Color

BROWN

Live

L

Yellow or Brass

BLUE

Neutral

N

Silver

YELLOW/GREEN

Earth

EG (Ground)

Green

 

 

 

 

Mounting

Orientation

This fixture can be mounted on a truss using a clamp in any position or against a flat surface using the brackets provided.

Rigging

The fixture includes a mounting yoke to which 1 rigging clamp can be bolted and (2) Flush Mount Brackets for flush mounting to flat surfaces. You must supply your own clamp and make sure the clamp is capable of supporting the weight of this fixture. You can order C-clamps from any CHAUVET dealer or distributor.

1.Block access below the work area and use suitable and stable platform when installing or servicing fixture.

2.Align the clamp screw with the center hole on the yoke and tighten.

3.Verify the structure can hold 10 times the weight of all to-be installed fixtures.

4.Adjust the angle on the yoke arm as necessary.

5.Always use a safety cable or chain as a secondary source of attachment. The safety cable must hold 10 times the weight of the fixture. If safety cable attachment point is provided that is permanently affixed to the surface or body of the fixture, use that instead of looping through a hanging yoke/arm.

Flush Mounting

Hanging Clamp

Flush Mounting Bracket

1.Draw a screw hole template on a large piece of vellum or transparent paper for best alignment.

2.Place paper against the mounting surface and drill holes or mark the surface for drilling.

3.Hang Panel.

TFX-UVLED User Manual

7

2006-10-11/12:19

Image 7
Contents LED Shadow Table of Contents Your shipment includes the following Before You BeginUnpacking Instructions Contact UsProtection against exposure to UV Ultraviolet Radiation Important Safety InformationProtection against Electric Shock Protection against Fire & BurnsIntroduction FeaturesDMX Channel Summary Product Overview AC Power SetupMounting Fixture Linking Cable ConnectorsDMX Data Cable Pin to 5-Pin Conversion Chart Setting up a DMX Serial Data LinkStandalone/Master-Slave Fixture Linking Setup Standalone ModeOperating Instructions Daisy Chain Serial Data Link DMX Control ModeDMX Primer Returns ProcedureMaintenance AppendixBinary & DMX DIP-switch Addressing DMX & Binary Address Quick Reference Chart Binary Addressing Quick Reference ChartDMX Channel Values Technical Support Technical Specifications