Equinox Systems RS232-RS485 manual Equinox Warranty Information

Page 4

Equinox Warranty Information

This product is guaranteed by Equinox Technologies UK Limited for a period of 12 months (1 year) after the date of purchase against defects due to faulty workmanship or materials. One guarantee covers both parts and labour. Service under the guarantee is only provided upon presentation of reasonable evidence that the date of the claim is within the guarantee period (e.g. completed registration/guarantee card or a purchase receipt).

The guarantee is not valid if the defect is due to accidental damage, misuse or neglect and in the case of alterations or repair carried out by unauthorised persons. A number of exceptions to the warranty are listed in the ‘Exceptions to warranty’ section below. Service (during and after guarantee period) is available in all countries where the product is distributed by Equinox Technologies UK Limited.

Exceptions to warranty

i.Over-voltage damage

This warranty does not cover damage to the programmer due to voltages beyond the specified voltage limits being applied to the ‘DC Power Input’ or the ‘Target Connector’. The user must ensure that sufficient care is taken to avoid over-voltage and static conditions on any of the ‘Target Connector’ I/O pins.

ii.Over-current damage

This warranty does not cover damage to the programmer due to excessive current being drawn from the programmer power supply. The user must ensure that there is sufficient over-current protection within the test fixture to protect against short circuit loads.

iii.Short-circuit damage

This warranty does not cover damage to the programmer due to short-circuit loads being placed across programmer I/O lines.

Fixed price repair service

Equinox offer a fixed price repair service for the PPM programmer. Please contact Equinox directly for further information.

Disclaimer

Whilst every effort has been made to ensure that programming algorithms are correct at the time of their release, it is always possible that programming problems may be encountered, especially when new devices and their associated algorithms are initially released. It is Equinox’s Company Policy to endeavour to rectify any programming issues as quickly as possible after a validated fa ult report is received.

It is recommended that high-volume users always validate that a sample of a devices has been programmed correctly, before programming a large batch. Equinox Technologies UK Ltd. can not be held responsible for any third party claims which arise out of the use of this programmer including ‘consequential loss’ and ‘loss of profit’.

RS232-RS485 Convertor Manual V1.02 28/06/01

iii

Image 4
Contents User Guide Contents Copyright Information Equinox Warranty Information RS232-RS485 Convertor Manual V1.02 28/06/01 Electromagnetic Compatibility EMC Compliance ESD Points to rememberTechnical Support ? Internet Web Site? E-mail ? FaxAssociated Product Documentation Hardware Product DocumentationSoftware Downloading up-to-date documentation and softwarePage System Contents OverviewRS232-RS485 Convertor End Panels Number Description TypeInput Power Supply Requirements RS-232 to RS-485 Status LED IndicatorsLED Colour Status Description J1 RS-232 Serial Communications Port J1 Pin-outJ2 & J4 Isolated RS-485 Connectors J2 & J4 RS485 Connector Pin-outsPRO101 Multi-Channel RS-485 Operation OverviewPRO101 Hardware Installation Instructions PRO104 4 Channel Eurocard Rack Production ISP System PRO104/108 Hardware Installation Instructions

RS232-RS485 specifications

Equinox Systems RS232-RS485 is a crucial device in the realm of industrial communication, facilitating the seamless transition between RS232 and RS485 protocols. This converter is essential for applications where devices equipped with RS232 need to communicate over longer distances or in noisy environments where RS485 excels.

One of the main features of the Equinox Systems RS232-RS485 converter is its ability to support long cable runs. RS232 typically allows communication over short distances, typically up to 50 feet, while RS485 can extend this reach to over 4000 feet. This flexibility is vital in large industrial settings, where devices may be located far apart.

Another significant feature is its robust data transmission capabilities. RS485 is well-known for its differential signaling, which enhances noise immunity and allows for reliable communication in electrically noisy environments. The converter supports multi-drop configurations, enabling multiple devices to be connected on the same network without signal degradation.

The technology employed in the Equinox Systems RS232-RS485 converter includes advanced signal processing, which ensures high data integrity and reduces error rates during transmission. It typically operates at baud rates up to 115200 bps, making it suitable for various data-intensive applications.

In terms of compatibility, this converter is designed to work seamlessly with various devices, including PLCs, industrial sensors, and computers. Its ease of use is enhanced by features like auto-sensing, which automatically adjusts to the different communication settings of connected devices.

The design also prioritizes durability, featuring robust enclosures that protect against dust and moisture. This makes it suitable for operations in challenging environments, such as manufacturing plants and outdoor installations.

Additionally, the Equinox Systems RS232-RS485 converter is often equipped with LED indicators that provide real-time feedback on data transmission status, aiding in diagnostics and maintenance.

In summary, the Equinox Systems RS232-RS485 converter stands out for its versatility, reliability, and ease of integration into existing systems. Whether in industrial automation, building management, or extensive network systems, its ability to facilitate effective communication between devices using different protocols makes it an invaluable asset in modern communication solutions.