Equinox Systems RS232-RS485 manual Technical Support, ? Internet Web Site, ? E-mail, ? Fax

Page 7

Technical Support

It is often the case that users experience problems when installing or using a product for the first time. Equinox are unable to answer technical support questions about this product or its use by telephone.

If you have a technical support problem, please consult the following list for help:

?Manual

?On-line help

Press <F1> for help at any time.

The help system is context-sensitive. Simply press <F1> on any error message and the Possible causes of the error should be listed. This help system is updated on a regular basis. Please see software update details for information on keeping up -to-date with software revisions.

?Internet Web Site

Equinox have setup an AVR™ microcontroller support page on our web site. This page is designed to provide up-to date information on all issues concerning both AVR™ microcontrollers and support tools.

The microcontroller support page can be found at: www.equinox-tech.com

?E-mail

Please e-mail any technical support questions about this product to: support@equinox-tech.com

Equinox will try our best to answer your questions about this product as quickly as possible. However, we cannot promise an immediate reply. Please consult our web site for new software updates as the problem that you are enquiring about may have already been fixed in a new version.

?Fax

Please fax any technical support questions about this product to: +44 (0) 1204 535555

Equinox will try our best to answer your questions about this product as quickly as possible. However, we cannot promise an immediate reply. Please consult our web site for new software updates as the problem that you are enquiring about may have already been fixed in a new version.

vi

RS232-RS485 Convertor Manual V1.02 28/06/01

Image 7
Contents User Guide Contents Copyright Information Equinox Warranty Information RS232-RS485 Convertor Manual V1.02 28/06/01 ESD Points to remember Electromagnetic Compatibility EMC Compliance? Fax Technical Support? Internet Web Site ? E-mailDownloading up-to-date documentation and software Associated Product DocumentationHardware Product Documentation SoftwarePage Overview System ContentsNumber Description Type RS232-RS485 Convertor End PanelsInput Power Supply Requirements RS-232 to RS-485 Status LED IndicatorsLED Colour Status Description J1 Pin-out J1 RS-232 Serial Communications PortJ2 & J4 RS485 Connector Pin-outs J2 & J4 Isolated RS-485 ConnectorsOverview PRO101 Multi-Channel RS-485 OperationPRO101 Hardware Installation Instructions PRO104 4 Channel Eurocard Rack Production ISP System PRO104/108 Hardware Installation Instructions

RS232-RS485 specifications

Equinox Systems RS232-RS485 is a crucial device in the realm of industrial communication, facilitating the seamless transition between RS232 and RS485 protocols. This converter is essential for applications where devices equipped with RS232 need to communicate over longer distances or in noisy environments where RS485 excels.

One of the main features of the Equinox Systems RS232-RS485 converter is its ability to support long cable runs. RS232 typically allows communication over short distances, typically up to 50 feet, while RS485 can extend this reach to over 4000 feet. This flexibility is vital in large industrial settings, where devices may be located far apart.

Another significant feature is its robust data transmission capabilities. RS485 is well-known for its differential signaling, which enhances noise immunity and allows for reliable communication in electrically noisy environments. The converter supports multi-drop configurations, enabling multiple devices to be connected on the same network without signal degradation.

The technology employed in the Equinox Systems RS232-RS485 converter includes advanced signal processing, which ensures high data integrity and reduces error rates during transmission. It typically operates at baud rates up to 115200 bps, making it suitable for various data-intensive applications.

In terms of compatibility, this converter is designed to work seamlessly with various devices, including PLCs, industrial sensors, and computers. Its ease of use is enhanced by features like auto-sensing, which automatically adjusts to the different communication settings of connected devices.

The design also prioritizes durability, featuring robust enclosures that protect against dust and moisture. This makes it suitable for operations in challenging environments, such as manufacturing plants and outdoor installations.

Additionally, the Equinox Systems RS232-RS485 converter is often equipped with LED indicators that provide real-time feedback on data transmission status, aiding in diagnostics and maintenance.

In summary, the Equinox Systems RS232-RS485 converter stands out for its versatility, reliability, and ease of integration into existing systems. Whether in industrial automation, building management, or extensive network systems, its ability to facilitate effective communication between devices using different protocols makes it an invaluable asset in modern communication solutions.