Vidikron VL-40 manual 6Serial Communications, Serial Command Syntax, Serial Commands

Page 63

6Serial Communications

To interface the DView with a home theater automation/control system or a PC running terminal emulation software, connect it to your control system or PC as shown in Figure 3-11.

Configure the RS-232 controller or PC serial port as follows: no parity, 8 data bits, 1 stop bit and no flow control. Set the baud rate to match that of the DView RS-232 port; the default baud rate is 115200.

6.1

RS-232 Connection and Port Configuration

Commands are in ASCII format and are not case-sensitive.

A carriage return is not required after a command.

When you send a valid command, the DView executes it and acknowledges it with a right-bracket character (]) followed by the four-digit numeric code you sent; for example,

]0002.

When you send an invalid command (one followed by values outside the valid range for that command), the DView ignores it and returns >MAX or <MIN instead of the four-digit code.

When you send an unrecognized/misspelled command, the DView ignores it and returns -N/Ainstead of the four-digit code.

Table 6-1lists the RS-232 command set.

Table 6-1. Serial Commands

 

Command

 

 

Description

 

 

 

 

 

 

[

 

S3A

 

0###

Set audio volume to ### ( = 000-100)

 

 

 

 

Example: [S3A0075 sets volume to 75

 

 

 

 

 

 

[

 

+3A

 

 

Audio volume up

 

 

 

 

 

 

[

 

-3A

 

 

Audio volume down

 

 

 

 

 

 

[

 

S3E

 

000#

Audio mute (speakers/headphones)

 

 

 

 

 

0

= not muted, 1 = muted

 

 

 

 

Example: [S3E0001 mutes the audio output

 

 

 

 

 

 

[

 

S4A

 

000#

Main input selection

 

 

 

 

 

0

= TV

 

 

 

 

 

1

= Input1

 

 

 

 

 

2

= Input2

 

 

 

 

 

3

= Input3

 

 

 

 

 

4

= Input4

 

 

 

 

 

6

= RGB

 

 

 

 

 

8

= HDMI1

 

 

 

 

 

9

= HDMI2

 

 

 

 

Example: [S4A0006 selects RGB

 

 

 

 

 

 

[

 

+4A

 

 

Select “next” Main AV input

 

 

 

 

 

 

 

6.2

Serial Command Syntax

Vidikron VL-40 and VL-46 Owner’s Operating Manual

51

Image 63
Contents VL-40 and VL-46 Page For LCD Displays ONE Year Limited WarrantyRIGHTS, Limits and Exclusions Vidikron DOC Compliance Notice Safety Precautions1Table of Contents Serial Communications Maintenance and TroubleshootingSpecifications Operation1List of Figures List of Figures About This Manual 1IntroductionIf you need Turn to Using This ManualThey also provide supplemental information Performance or cause a malfunctionKey Features and Benefits Description, Features and BenefitsOptional Accessories Speakers Controls and Indicators2Controls and Functions DView at a GlanceRGB Headphone Jack Main Power SwitchPower Input 100 to 240 VAC Connect the DView to power here INPUT2 S-Video InputPC Audio Input INPUT3 Component Video RCA connectorsINPUT4 Component Video RCA connectors HDMI1/Computer Input Digital HDMI2/Computer Input DigitalDView Remote Control DView Remote ControlSource Selection Buttons Memory Preset ButtonsOFF / on Numeric ButtonsWide IntelliWide Aspect Ratio Selection Buttons ANA4X3 Letbox LetterboxMTS/SAP Multichannel Television Sound/Second Audio Program Timer OFF ButtonSound Control Buttons Surrnd SurroundControls and Functions 3Installation Remote ControlTo install batteries in the remote control Quick Setup Installation OverviewStep Procedure For Details, refer to Installation Considerations Wall-Mounting the DViewAmbient Light Rear Connector Access Connections to the DViewSource Components Hdmi Connections Rear of the Display Rear of the PC DVD/DTV STB AV OUT Connections Speakers Optional Connecting External10. Digital Audio Connection AmplifierConnector Pin Assignments ConnectionRear Panel Installation Turning on the Power 4OperationChanging the OSD Language Setting the PC Display Properties Using the On-Screen Menus Source Picture AdjustTimer SetupMain Menu SourceAspect Ratio Control Description Aspect Ratio SettingsPicture Adjust Perform the adjustments in the order listed hereTypical Gray Bar Pattern for Adjusting Contrast Gray Yellow Cyan Green Magenta Red Blue Typical Test Pattern for Adjusting Sharpness Audio Channel Timer Auto Adjust may take some time to complete, depending on SetupRating/Category Description FCC Ratings and Content CategoriesLetterbox Mode = Letterbox Operation Should be used by ISF-certified technicians only ISF Calibration100 DView Splash Screen Aspect Size Position PIPUsing Picture-In-Picture PIP HDMI1 HDMI2 Video Available Main and PIP Source CombinationsChanging the PIP Position Changing the PIP SizeChanging the PIP Aspect Ratio Images Audio Programs Swap button on the remote controlMono+SAP Broadcast Mode Receive Mode Mono StereoStereo Sound/SAP Compatibility with Stereo and SAP Audio BroadcastsOperation Symptom Possible Causes Solution 5Maintenance and TroubleshootingTroubleshooting Tips Troubleshooting ChartComputer Signal Command Description Serial Command SyntaxRS-232 Connection and Port Configuration Serial CommandsSAB SDB 0027 0024 Serial Communications DView Specifications 7SpecificationsSpecifications are subject to change without notice Weight Regulatory Approvals Limited WarrantyVL-40 Dimensions DView DimensionsView Computer/Video Signal Compatibility Chart Computer Signal CompatibilitySignal Mode Vertical Frequency Horizontal Specifications Page Vidikron