ClearCube F6151 Media Converter and Chassis System
•First, disconnect the converter from the power. Then toggle Pin 2 of the DIP switch to the up position to enable the forced mode for TX port.
NOTE Pin 2 must be toggled up prior to speed and duplex mode settings manually.
•Toggle down Pin 3 to force the TX port at the speed of 100Mbps. Or toggle up Pin 3 for 10Mbps speed.
•Toggle down Pin 4 to force the TX port at full duplex mode. Or toggle up Pin 4 for half duplex mode.
•Toggle down Pin 5 to force the FX port at full duplex mode. Or toggle up Pin 5 for half duplex mode.
•Connect the converter to the power again. The new setting will come into effect then.
Front Panel & LEDs
LED INDICATORS
The LED indicators give you instant feedback on status of the converter:
LEDs | State | Indication |
PWR | Steady | Power on |
|
| PWR stands for POWER |
| Off | Power off |
100 (Mbps) | Steady | Connection at the speed of |
|
| 100Mbps |
| Off | Connection at the speed of 10Mbps |
LNK/ACT | Steady | A valid network connection |
|
| established |
|
| LNK stands for LINK |
| Flashing | Transmitting or receiving data |
|
| ACT stands for ACTIVITY |
User’s Guide | 11 |