Runco SP-60DHD / SP-60DHDXA, SP-50DHD / SP-50DHDXA, SP-42DHD / SP-42DHDXA Image Preset Commands

Page 65

Serial Communications

Table 6-1. Serial Commands (continued)

Command

Parameter

 

Value

Description

(min/max)

 

Stored?

 

 

 

 

 

 

 

 

Picture Adjust Commands

 

 

 

 

 

BRIGHTNESS

-100/100

 

YES

Sets a value for brightness

 

 

 

 

 

BRIGHTNESS?

NA

 

NA

Returns brightness setting value

 

 

 

 

 

CHROMADELAY

-12/12

 

YES

Sets a value for input color chroma delay

 

 

 

 

 

CHROMADELAY?

NA

 

NA

Returns input color chroma delay setting

 

 

 

 

 

COLOR

-100/100

 

YES

Sets a value for color

 

 

 

 

 

COLOR?

NA

 

NA

Returns color setting value

 

 

 

 

 

CONTRAST

-100/100

 

YES

Sets a value for contrast

 

 

 

 

 

CONTRAST?

NA

 

NA

Returns contrast setting value

 

 

 

 

 

FILMMODE

0/1

 

YES

Sets Film Mode off (0) or on (1)

 

 

 

 

 

FILMMODE?

NA

 

NA

Returns Film Mode setting (0 = off; 1 = on)

 

 

 

 

 

FILTER

0/15

 

YES

Sets a value for input color noise filter

 

 

 

 

 

FILTER?

NA

 

NA

Returns input color noise filter setting

 

 

 

 

 

PHASE

0/3

 

YES

Adjusts phase

 

 

 

 

 

PHASE?

NA

 

NA

Returns phase setting value

 

 

 

 

 

SHARPNESS

-6/6

 

YES

Sets a value for sharpness

 

 

 

 

 

SHARPNESS?

NA

 

NA

Returns sharpness setting value

 

 

 

 

 

TINT

-100/100

 

YES

Sets a value for tint

 

 

 

 

 

TINT?

NA

 

NA

Returns tint setting value

 

 

 

 

 

 

 

Image Preset Commands

 

 

 

 

 

CUSTOM1

NA

 

YES

Loads “Custom 1” image preset

 

 

 

 

 

CUSTOM2

NA

 

YES

Loads “Custom 2” image preset

 

 

 

 

 

DAY

NA

 

YES

Loads “ISF Day” image preset

 

 

 

 

 

NIGHT

NA

 

YES

Loads “ISF Night” image preset

 

 

 

 

 

PRESET?

NA

 

NA

Returns currently-selected preset

 

 

 

 

(ISF Day, ISF Night, Custom 1 or Custom 2)

 

 

 

 

 

PlasmaWall SP Series Owner’s Operating Manual

55

Image 65
Contents OW N E R ’S OP E R a T I N G MA N U a L Page For Plasma Displays Three Year Limited WarrantyRIGHTS, Limits and Exclusions Runco INTERNATIONAL, INC Safety Precautions Table of Contents Specifications Maintenance and TroubleshootingAppendix A. PlasmaWall Service Remote Control OperationList of Figures List of Figures About This Manual IntroductionIf you need Turn to Using This ManualKey Features and Benefits Description, Features and BenefitsOptional Accessories PlasmaWall at a Glance Controls and IndicatorsControls and Functions PlasmaWall Model SP-42DHD Rear Panel PlasmaWall Model SP-50DHD Rear Panel PlasmaWall Model SP-60DHD Rear Panel Digital RGB Input 2 DVI-D Main Power SwitchExternal Speaker Output Right External Speaker Output LeftDHD Controller Front Panel Power ButtonRunco Icon IR SensorLeft Button UP ButtonEnter Button Down ButtonDHD Controller Rear Panel Component Video RCA connectorsDVI OUT Inputs 3. DVI 1 / DVI 2 DigitalMain AC Fuse Composite Video InputRS-232 Control Port DHD Controller Remote Control DHD Controller Remote ControlEnter IR Output IndicatorLight MenuSVC CinemaISF Night ISF DAYRemote Control InstallationOther surfaces Step Procedure For Details, refer to Quick SetupConsiderations InstallationHigh-Altitude Operation Mounting the PlasmaWallVentilation Ambient LightInstallation Connections to the PlasmaWall and DHD Controller Connecting PlasmaWall to the DHD ControllerRS-232 Connection from the DHD Controller to the PlasmaWall Components to the DHD Connecting SourceDVI Connections See Figure DVI Source DVD Player or HD Tuner with Hdmi or DVI outDigital DTV RGB Connections Digital DTV RGB Connections SeePersonal Computer Refer to Computer/Video Signal Compatibility on page 64 forAnalog Computer RGB Connections See Figure DVD Player, VCR Satellite Receiver Laser Disc etc Composite/S-Video/Component Video Connections See FigureConnection Connecting 12-Volt Trigger Outputs to External EquipmentRS-232 Controller 11. Installing the Cable Ties Operation Turning on the PowerYou must enter a passcode to access the Service menu Operation Using the On-Screen Menus Service ISF PresetsInput Source Aspect RatioInput Source Main MenuAspect Ratio HD Pass Thru 1 HD Pass ThruRemote Aspect Ratio Control Description Key Aspect Ratio SettingsPicture Brightness Contrast Color Tint Sharpness PictureTypical Gray Bar Pattern for Adjusting Contrast Gray Yellow Cyan Green Magenta Red Blue Input Position Left/Right Up/Down Width Height Overscan Input PositionISF Presets ISF Night ISF Day Custom Save Factory Default ISF PresetsInformation Serial Number Hardware Firmware 0002.034B Date Nov 25Calibration Gain/Offset Refer to ISF Night Display Color, aboveOperation Service HD/RGB 1 and HD/RGB 2 Color Space Select Auto, RGB or YUV Do not change the Type setting in this menuOperation Operation Cleaning Maintenance and TroubleshootingCleaning the Display Panel Body and Remote Control Cleaning the ScreenSymptom Possible Causes Solution Troubleshooting TipsComputer/Video Signal Maintenance and Troubleshooting Letterbox Enter Serial CommunicationsValue Description Min/max Stored? Power On/Off Commands CommandInput Selection Commands Aspect Ratio CommandsImage Preset Commands Output Shift Commands Value Description Min/max Stored? Input Position CommandsBkgnd Enter key Command Parameter min/max Value Stored? DescriptionPlasmaWall Specifications SpecificationsModel SP-42DHD Model SP-50DHDDHD Controller Specifications PlasmaWall Dimensions14.8 34.3 49.1 M8 Screw Input Refresh Rate Resolution Remarks Computer/Video Signal CompatibilityHoriz KHz56.0 45.1 Specifications Overview Figure A-1. PlasmaWall Service Remote ControlAspect Ratio RGB SetupRGB-HD DVI-DReduction Service/Setup MenuVideo NR Noise PlasmaWall Service Remote Control Page Runco CL-810 Owner’s Operating Manual