Runco SP-50DHD / SP-50DHDXA, SP-42DHD / SP-42DHDXA manual RS-232 Controller, Connection

Page 39

Installation

Use a standard, 9-pin RS-232 cable to connect a PC or home theater control/automation

RS-232 Controller

system (if present) to the RS-232 Control port on the DHD Controller; see Figure 3-9.

Connection

For more information about using this connection, refer to Serial Communications on

 

page 53.

 

 

 

 

 

5

4

3

2

1

 

 

 

 

TRIGGERS

 

 

 

 

1

2

3

IR

Pb

Pr

Y

S-Video 1

 

 

 

Component Video

Video

S-Video 2

RS-232 Out

RS-232 Control

9 8 7 6

2Transmit Data

3Receive Data

5Ground

(none of the other pins are used)

to Automation/ Control System or PC

Figure 3-9. RS-232 Control System Connection

If your home theater contains equipment that responds to 12-Volt triggers, connect it to the 12-Volt trigger outputs as shown in Figure 3-10.

Connecting 12-Volt

Trigger Outputs to

External Equipment

 

 

 

TRIGGERS

 

 

 

 

1

2

3

IR

Pb

Pr

Y

S-Video 1

 

 

 

Component Video

Video

S-Video 2

RS-232 Out

RS-232 Control

3.5-mm mini plug

to 12-Volt

 

Sleeve = Ground

trigger-activated

 

 

 

 

Tip = +12V

 

equipment

 

 

 

 

 

Figure 3-10. Connecting 12-Volt Trigger Outputs

PlasmaWall SP Series Owner’s Operating Manual

29

Image 39
Contents OW N E R ’S OP E R a T I N G MA N U a L Page For Plasma Displays Three Year Limited WarrantyRIGHTS, Limits and Exclusions Runco INTERNATIONAL, INC Safety Precautions Table of Contents Operation Maintenance and TroubleshootingSpecifications Appendix A. PlasmaWall Service Remote ControlList of Figures List of Figures About This Manual IntroductionIf you need Turn to Using This ManualKey Features and Benefits Description, Features and BenefitsOptional Accessories Controls and Indicators Controls and FunctionsPlasmaWall at a Glance PlasmaWall Model SP-42DHD Rear Panel PlasmaWall Model SP-50DHD Rear Panel PlasmaWall Model SP-60DHD Rear Panel External Speaker Output Left Main Power SwitchDigital RGB Input 2 DVI-D External Speaker Output RightIR Sensor Power ButtonDHD Controller Front Panel Runco IconDown Button UP ButtonLeft Button Enter ButtonInputs 3. DVI 1 / DVI 2 Digital Component Video RCA connectorsDHD Controller Rear Panel DVI OUTComposite Video Input RS-232 Control PortMain AC Fuse DHD Controller Remote Control DHD Controller Remote ControlMenu IR Output IndicatorEnter LightISF DAY CinemaSVC ISF NightRemote Control InstallationOther surfaces Step Procedure For Details, refer to Quick SetupMounting the PlasmaWall InstallationConsiderations High-Altitude OperationVentilation Ambient LightInstallation Connections to the PlasmaWall and DHD Controller Connecting PlasmaWall to the DHD ControllerRS-232 Connection from the DHD Controller to the PlasmaWall DVI Source DVD Player or HD Tuner with Hdmi or DVI out Connecting SourceComponents to the DHD DVI Connections See FigureDigital DTV RGB Connections Digital DTV RGB Connections SeeRefer to Computer/Video Signal Compatibility on page 64 for Analog Computer RGB Connections See FigurePersonal Computer DVD Player, VCR Satellite Receiver Laser Disc etc Composite/S-Video/Component Video Connections See FigureConnecting 12-Volt Trigger Outputs to External Equipment RS-232 ControllerConnection 11. Installing the Cable Ties Operation Turning on the PowerYou must enter a passcode to access the Service menu Operation Using the On-Screen Menus Aspect Ratio ISF PresetsService Input SourceHD Pass Thru 1 HD Pass Thru Main MenuInput Source Aspect RatioRemote Aspect Ratio Control Description Key Aspect Ratio SettingsPicture Brightness Contrast Color Tint Sharpness PictureTypical Gray Bar Pattern for Adjusting Contrast Gray Yellow Cyan Green Magenta Red Blue Input Position Left/Right Up/Down Width Height Overscan Input PositionSerial Number Hardware Firmware 0002.034B Date Nov 25 ISF PresetsISF Presets ISF Night ISF Day Custom Save Factory Default InformationCalibration Gain/Offset Refer to ISF Night Display Color, aboveOperation Service HD/RGB 1 and HD/RGB 2 Color Space Select Auto, RGB or YUV Do not change the Type setting in this menuOperation Operation Cleaning the Screen Maintenance and TroubleshootingCleaning Cleaning the Display Panel Body and Remote ControlSymptom Possible Causes Solution Troubleshooting TipsComputer/Video Signal Maintenance and Troubleshooting Letterbox Enter Serial CommunicationsAspect Ratio Commands CommandValue Description Min/max Stored? Power On/Off Commands Input Selection CommandsImage Preset Commands Output Shift Commands Value Description Min/max Stored? Input Position CommandsBkgnd Enter key Command Parameter min/max Value Stored? DescriptionModel SP-50DHD SpecificationsPlasmaWall Specifications Model SP-42DHDDHD Controller Specifications PlasmaWall Dimensions14.8 34.3 49.1 M8 Screw KHz Computer/Video Signal CompatibilityInput Refresh Rate Resolution Remarks Horiz56.0 45.1 Specifications Overview Figure A-1. PlasmaWall Service Remote ControlDVI-D RGB SetupAspect Ratio RGB-HDService/Setup Menu Video NR NoiseReduction PlasmaWall Service Remote Control Page Runco CL-810 Owner’s Operating Manual