Sanyo CE52SR1 instruction manual RS232C Command Tables

Page 16

RS232C Command Tables

Functional Execution Command Table

Command

C00

C01

C24

C25

C26

C27

C28

C29

C0F

C70

C71

C72

C73

C74

C75

C76

C64

C92

CF PSAVE ON

CF PSAVE OFF

CF CLOK ON

CF CLOK OFF

CF DEA RMCY

CF DEA RMCN

Image control Read Command Table

Item

POWER ON

POWER OFF

Wide “Natural” direct Wide “Zoom 16:9” direct Wide “Title in 16:9” direct Wide “Zoom 14:9” direct Wide “Title in 14:9” direct Wide “Full” direct Wide “Normal” direct AV1 direct

RGB direct

AV2 RGBHV direct AV2 YPbPr direct AV3 direct

DVI direct

PC direct

PC Auto adjust

Factory settings

Power save ON

Power save OFF

Child lock ON

Child lock OFF

RC inhibition OFF

RC inhibition ON

Status read command

 

Item

CR BRIGHT

Status of Brightness.

CR CONT

Status of Contrast.

CR COLOR

Status of Color.

CR TINT

Status of Tint.

CR SHARP

Sharpness.

CR WBAL

Status of White Balance Mode information.

CR WBAL-R

Status of White Balance Red

CR WBAL-G

Status of White Balance Green

CR WBAL-B

Status of White Balance Blue

CR NZRED

Status of Noise reduction setting.

CR FILM

Status of Film mode setting.

CR IMAGE

Status of Image selection.

 

The same as PICTURE mode

 

 

CR DCDI

Status of DCDi setting.

CR ACCACM

Status of ACC/ACM setting.

CR CCS

Status of CCS setting.

CR MPEGNR

Status of MPEG NR setting.

PC Read Command Table

 

 

 

 

 

Status read command

 

Item

CR H-POS

Status of Horizontal position.

CR V-POS

Status of Vertical position.

CR PHASE

Status of PHASE value.

CR CLOCK

Status of CLOCK value.

Input Read Command Table

 

 

 

 

 

Status read command

 

Item

CR INPUT

 

Status of Input selection.

CR SOURCE

 

Status of Input source mode.

CR SYSTEM

 

Status of system of Input mode.

Screen Read Command Table

 

 

 

Status read command

 

Item

CR SCREEN

Status of screen size The same of WIDE mode

42

Image 16
Contents Monitor de LCD LCD Monitor Moniteur daffichage à cristaux liquidesEspañol Página Safety Precautions Installation and UseImportant UK only Additional for North America and CanadaServicing ServicingImportant recycling information Declaration of Conformity North America and Canada AC Power Cord RequirementEnd-User License Mains Connection InstallationConnections Remote Control Switching into/from standby mode Controls and MenusMenu Operation Picture menuSetup menu Menu OperationSound menu Time menuPC Adj. menu Installation Mode Installation ModeSetting Procedure DCROperation Selection of picture sizePIP1, PIP2, POP or OFF mode PIP1 mode OFF mode PIP2 mode POP modePIP/POP Operation Operation in Text Mode Teletext OperationSpecification Helpful hints PC/DVI-D / Component Signal Support Timing List RS232C Command Tables RS232C Command Tables Part No KA6P1P0456-- N5VYS