B&B Electronics 1939STB manual RS-232 Baud Rate Change cont’d

Page 12

RS-232 Baud Rate Change - cont’d.

All baud rates are entered as hex numbers. To determine the decimal divisor use the following formula. The decimal number must be converted to hexadecimal before entering the number into byte 6 and 7. Baud rates faster than 57,600 are not supported.

UART clock = 7,372,800 Hz

Decimal Divisor = Clock frequency (7,372,800)

Baud output x 16

If you want a baud rate output of 300 baud:

Decimal Divisor = 7,372,800 300 x 16

Decimal Divisor = 1536 = 600 hex

Baud 1= 00

Baud 2= 06

Programming a baud rate change to 300 baud, 1 stop bit, 8 bit data, no parity.

Table 13. Baud Rate Setup

Byte

Byte

Byte 3

Byte 4

 

 

Byte 5

 

 

Byte 6

 

 

Byte 7

 

1

2

Nibble 2

Nibble 1

Nibble 2

Nibble 1

 

UB3

 

 

Baud 1

 

 

Baud 2

 

81

21

0010

0011

0000

0010

 

 

 

 

 

 

 

 

 

81

21

23 hex

02 hex

 

03 hex

 

 

00 hex

 

 

06 hex

 

Table 13 is set to produce a baud rate of 300, 1stop bit, an 8 bit data word, and no parity.

10

1939STB4600 Manual

 

B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100

- Fax 815-433-5104

 

B&B Electronics Ltd – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91 792444

– Fax +353 91 792445

Image 12
Contents RS-232 to J1939 Converter CE Model 1939STBTable of Contents Introduction SAE Publications1939STB4600 Manual Description Electrical Specification Physical DescriptionCommunication directed to the device Format Control Byte Byte 3 Nibble Byte Vendor String Setup Internal FunctionsVendor String Message Received from the SAE-J1939 BusBaud Rate Setup RS-232 Baud ChangeRS-232 Baud Rate Change cont’d Parity Setup Byte 5 UB3Stop Bit Setup Word LengthExternal Commands J1939 FormatMessage Header Setup Valid Codes for ByteMessage Information J1939 Message Information Two Bit Values for Byte 5Byte IntpndTransmit XTD Bit2 DLC DIRSAE-J1939 Control Header J1939 Message Frame1939STB4600 Manual Byte Shown in Table1939STB4600 Manual Byte 1939STB4600 Manual Bytes 9 1939STB4600 Manual DLC Data Length Code DIR Message DirectionData Field Reception of Data SAE-J1939 BusID Byte Function Internal Messages Installation Software1939STB4600 Manual Message Transmission sending data to the 1939STB Saving Message Information File LoggingAppendix A. The Extended can / SAE-J1939 Message Frame Arbitration Field Appendix B. Example