B&B Electronics 1939STB manual Byte

Page 9

Control Byte 4

When control byte 3 is set to “external commands” (bit 4 set to 1), nibble 1 of control byte 4 is used to tell the J1939 in which message slot location (1 through 15) to place the message data. NOTE: Message location number 15 is receive only.

Table 7. Byte 4

 

 

Nibble 2

 

 

Nibble 1

 

 

Bit 7

Bit 6

 

Bit 5

Bit 4

Bit 3

Bit 2

 

Bit 1

Bit 0

When control byte 3 is set to “ internal commands” (bit 5 set to 1), nibble

1 of control byte 4 has the following functions:

 

Table 8. Nibble 1 Bit Values

Nibble 1 Value

 

Function

0001

 

Display vender number & version

0010

 

Set baud rate, stop, start bits

0100

 

Not used

1000

 

Not used

Nibble 2 of control byte 4 is reserved for future use and is set to 0.

1939STB4600 Manual

7

B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104

B&B Electronics Ltd – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91 792444 – Fax +353 91 792445

Image 9
Contents Model 1939STB RS-232 to J1939 Converter CETable of Contents SAE Publications Introduction1939STB4600 Manual Description Physical Description Electrical SpecificationCommunication directed to the device Format Byte 3 Nibble Control ByteByte Internal Functions Vendor String SetupVendor String Message Received from the SAE-J1939 BusRS-232 Baud Change Baud Rate SetupRS-232 Baud Rate Change cont’d Byte 5 UB3 Parity SetupWord Length Stop Bit SetupJ1939 Format External CommandsValid Codes for Byte Message Header SetupTwo Bit Values for Byte 5 Message Information J1939 Message InformationIntpnd ByteTransmit DLC DIR XTD Bit2J1939 Message Frame SAE-J1939 Control Header1939STB4600 Manual Shown in Table Byte1939STB4600 Manual Byte 1939STB4600 Manual Bytes 9 1939STB4600 Manual DIR Message Direction DLC Data Length CodeData Field Reception of Data SAE-J1939 BusID Byte Function Internal Messages Software Installation1939STB4600 Manual Message Transmission sending data to the 1939STB File Logging Saving Message InformationAppendix A. The Extended can / SAE-J1939 Message Frame Arbitration Field Appendix B. Example