MC100FX-SC2/30-A User’s Guide
2.Launch a
Typically, the instructions will be similar to the following:
Enter the number of test messages (frame packets) to be sent (between 1 and 1000).
Click on the START button.
The program will send a testing message that will loop in the fiber segment, it will then display a pass/fail result.
Note
Be sure to deactivate both local and remote
NWay DIP-switch Setting
Use the NWay DIP switch to activate NWay operations.
Factory Default: NWay DIP switch set to ON position. Check that the networking device that will be connected to the Converter supports NWay.
If YES: Check that the NWay DIP switch is set to the ON position. The Converter will automatically set the optimum speed and duplex mode on the copper segment. Users can skip the settings for DIP switches 2 and 3 when NWay is activated.
If NO: Set the NWay DIP switch to the OFF position.
Then use DIP switch 2 to manually select between half- (HD) and
Important
In order to configure DIP switches 2 (duplex mode) and 3 (speed), you must set DIP switch 1 (NWay) to the OFF position
10