Transition Networks SGETF1017-100 Cable Specifications, Fiber Cable, Copper Cable, Install Cable

Page 3

CABLE SPECIFICATIONS

Fiber Cable

MULTIMODE

Fiber Optic Cable Recommended:

62.5 / 125 µm multimode fiber

Optional:

100 / 140 µm multimode fiber

 

85 / 125 µm multimode fiber

 

50 / 125 µm multimode fiber

SGETF1013

850 nM

 

Fiber Optic Transmitter Power:

min: -10.0 dBm

max: -4.0 dBm

Fiber Optic Receiver Sensitivity:

min: -17.0 dBm

max: -0.0 dBm

Link Budget:

7.0 dB

 

Typical Maximum Cable Distance*:

220 meters

 

SGETF1018

850 nM

 

Fiber Optic Transmitter Power:

min: -9.5 dBm

max: -4.0 dBm

Fiber Optic Receiver Sensitivity:

min: -17.0 dBm

max: -0.0 dBm

Link Budget:

7.0 dB

 

Typical Maximum Cable Distance*:

220 meters

 

SINGLEMODE

Fiber Optic Cable Recommended:

9 µm singlemode fiber

SGETF1014

1300 nM

 

Fiber-optic Transmitter Power:

min: -13.0 dBm

max: -3.0 dBm

Fiber-optic Receiver Sensitivity:

min: -20.0 dBm

max: -3.0 dBm

Link Budget:

7.0 dB

 

Typical Maximum Cable Distance*:

5 kilometers

 

SGETF1015

1300 nM

 

Fiber-optic Transmitter Power:

min: -5.0 dBm

max: -0.0 dBm

Fiber-optic Receiver Sensitivity:

min: -20.0 dBm

max: -3.0 dBm

Link Budget:

15.0 dB

 

Typical Maximum Cable Distance*:

25 kilometers

 

SGETF1017

1550 nM

 

Fiber-optic Transmitter Power:

min: -3.0 dBm

max: -2.0 dBm

Fiber-optic Receiver Sensitivity:

min: -23.0 dBm

max: -3.0 dBm

Link Budget:

20.0 dB

 

Typical Maximum Cable Distance*:

65 kilometers

 

SGETF1025

1550 nM

 

Fiber-optic Transmitter Power:

min: -9.5 dBm

max: -3.0 dBm

Fiber-optic Receiver Sensitivity:

min: -20.0 dBm

max: -3.0 dBm

Link Budget:

20.0 dB

 

Typical Maximum Cable Distance*:

65 kilometers

 

*Actual distance dependent upon physical characteristics of network installation.

Copper Cable

Category 5 twisted-pair copper wire is required. Either shielded twisted-pair (STP) or unshielded twisted-pair (UTP) can be used. DO NOT USE FLAT OR SILVER SATIN WIRE.

CATEGORY 5:

Gauge

24 to 22 AWG

Attenuation

22.0 dB /100m @ 100 MHz

Maximum Cable Distance:

100 meters

The Gigabit Ethernet™ network uses all four wire pairs. The active pairs are pins 1 & 2, pins 3 & 6, pins 4 & 5, and pins 7 & 8. Use only dedicated wire pairs (such as blue/white

&white/blue, orange/white & white/orange) for the active pins. NOTE: Straight- through/crossover configuration is automatic.

Install Cable

COPPER

NOTE: The SGETF10xx series media converter auto-negotiationfeature allows the media converter to bring up the copper link in the highest mode possible for ALL the attached network devices.

1.Locate or build 1000BASE-TX-compliant cables with male RJ-45 connectors installed at both ends.

2.Connect RJ-45 connector at one end of cable to media converter RJ-45 port connector.

3.Connect RJ-45 connector at other end of cable to 1000BASE-TX- compliant device RJ-45 port connector.

FIBER

1.Locate or build 1000BASE-SX/LX-compliant fiber cable with male two-stranded TX to RX connectors installed at both ends.

TX

TX

RX

RX

2.Connect cable with connector installed at TX location on media converter to RX location on attached device.

3.Connect cable with connector installed at RX location on media converter to TX location on attached device.

Power the Media Converter

1.Install power adapter cord at back of media converter.

2.Connect power adapter plug to AC power.

3.Verify that media converter is powered by observing illuminated LED(s).

Image 3
Contents Compliance Information Installation Technical SpecificationsSet 4-Position Switch Fiber Cable Cable SpecificationsInstall Cable Power the Media ConverterUsing Status LEDs OperationYES