Specifications

Other Specifications

Specification

Description

 

 

Switch Fabric

Full digital, nonblocking

 

 

Electrical

35 watts (120 BTUs/hr) per PARTNER Endeavor 362 processor module during normal power consumption

Specifications

45 watts (154 BTUs/hr) per PARTNER Endeavor 362 processor module during maximum power consumption

 

30 watts (105 BTUs/hr) per 362EC expansion module during normal power consumption

 

40 watts (140 BTUs/hr) per 362EC expansion module during maximum power consumption

 

45 days to 6 months memory backup with 2 AAA-size standard alkaline batteries (IEC LR03)

 

 

Processor Module

68306 16 Mhz processor

Specifications

256Kbyte RAM

 

512Kbyte FLASH ROM

 

Custom VLSI DSP ASIC—16bit, 52 Mhz

 

—VLSI = Very Large Scale Integration

 

—DSP = Digital Signal Processor

 

—ASIC = Application Specific Integrated Circuit

 

 

Extension Jack

Ringing voltage: +55VRMS Balanced ringing within a trapezoidal wave shaping

Specifications

38- to 42-volt talk battery

(Endeavor

Ringing frequency: 20 HZ

 

Processor and

 

362EC module)

 

 

 

Music-On-Hold

Accepts 2 volts at 50 Kohms maximum input

Jack Specifications

0 – 18 dB attenuation

 

 

Environmental

Mount on a wall at least 2 feet (0.6 meters) from the floor (wall mounting required)

Requirements-

Locate within 5 feet (1.5 meters) of the network interface jacks and a properly grounded electrical outlet not

Control Unit

controlled by a switch, using supplied 7-foot (2.1-meter) cords

 

Operating temperature 32° to + 104°F (0° to + 40°C), not in direct sunlight

 

Humidity 15% – 90%, noncondensing

 

For proper ventilation and easy replacement of modules, provide the following minimum clearance around the

 

control unit:

 

—5-Slot Carrier: 1 foot (0.3 meter) clearance at the top and sides and 2 feet (0.6 meter) at the front and bottom

 

—2-Slot Carrier or Stand-alone Endeavor processor module: 1 foot (0.3 meter) clearance at the front, top and

 

right side, and 2 feet (0.6 meter) at the bottom and left side

 

Locate in an area free of excess moisture, corrosive gases, dust, and chemicals

 

 

Electrical

U.S. and Canada: 90-130 VAC, 50-60 Hz, 3-prong outlet separate ground, separately fused at 15 Amps

Requirements-

Grounding to comply with Underwriters Laboratories (UL) 1459:

Control Unit

A. An insulated grounding conductor that is not smaller in size and equivalent in insulation material and

 

 

thickness to the grounded and ungrounded branch circuit supply conductors, except that it is green with or

 

without one or more yellow stripes, is to be installed as part of the circuit that supplies the product or

 

system

 

B. The grounding conductor mentioned in item A is to be connected to ground at the service equipment

 

C. The attachment-plug receptacles in the vicinity of the product or system are all to be of a grounding type,

 

and the grounding conductors serving these receptacles are to be connected to earth ground at the service

 

equipment

 

 

 

(continued)

A-2

Page 367
Image 367