Feature Reference

Programming

(See Figure 2-2on page 2-19for the location of special programming buttons such as sand eon system phones.)

To change the hold disconnect time:

1.Press f00ss#203at extension 10 or 11.

2.At the Line: prompt, enter the two-digit number of the line for which you are adjusting the hold disconnect time.For example, to adjust line 1, press

01.

The current hold disconnect time for the line number you specified is displayed. For example, if line 1 is set to the default setting, 09 – 450 msec shows in the display.

3.To change the hold disconnect time, press Duntil the appropriate value displays.

4.To program the next line, press n, then repeat Step 3.

5.Repeat Step 4 for each line in the system.

6.Select another procedure or exit programming mode.

5-118

Page 217
Image 217
Lucent Technologies 518-458-100 manual Programming, 118